Welcome Thank you and congratulations on choosing Parweld. This Owner’s Manual is designed to help you get the most out of your Parweld products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards in the workplace. With proper maintenance this equipment should provide years of reliable service.
Maintain unit according to manual. Wear a safety harness if working above floor level. Keep all panels and covers securely in place. Clamp work cable with good metal-to-metal contact to work piece or worktable as near the weld as practical. www.parweld.co.uk...
The XTM 304C is a complete semiautomatic constant voltage DC arc welding machine built to meet CE specifications. It combines a constant voltage power source and a constant speed wire feeder FLYING METAL can injure eyes.
3.0 Technical Specifications The XTM 304C is a compact type machine with integrated wire feed unit for use with 3 phase 400V supply. Feature XTM 304C Supply voltage [V] 3 x 400 ± 10% Supply frequency 50 / 60 Hz Supply current, max.
Plasma welding torches. Remove the tip adaptor and contact tip The Parweld XTS recirculation equipment can be fitted with a fail- safe flow protection device to prevent overheating or meltdown. Inch the wire from the exit of the wire guide on the feed unit as Figure 1.
Soft Start. The soft start control slows the acceleration of the wire feed motor as the act starts and so reduces wire snubing and spatter at the weld start. This control should be adjusted to give a smoother start to the weld. (9). www.parweld.co.uk...
Reduce travel speed. Burn-Through - weld metal Excessive heat input. Select melting lower voltage range and reduce wire feed speed. Completely through base metal Increase and/or maintain Resulting in holes where no steady travel speed. metal remains. www.parweld.co.uk...
" BSP inlet and outlet connections Stock Code Description 706101 Flow Meter Mixed Gas 25 lpm (MIG) Gas flow Tester • Designed to check gas flow at the front of MIG Torches. Stock Code Description 806001 Gas flow Tester www.parweld.co.uk...
9.0 EC Declaration of Conformity Hereby we declare that the machines as stated below Type: XTM 304C Conform to the EC Directives: Low Voltage Directive 2014/35/EEC EMC Directive 2014/35/EEC Harmonised European standard: EN/IEC 60974-1, EN/IEC 60974-10 This is to certify that the tested sample is in conformity with all provisions of the above detailed EU directives and product standards.
WEE compliance outside the UK please contact your supplier/Importer Parweld is registered with a compliance scheme Official registration number is WEE/FD0255QV When your equipment reaches the end of its service life you should return it to Parweld where it will be reconditioned or processed for recycling.
Page 17
Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire England DY12 2TZ Tel. +44 1299 266800 www.parweld.co.uk info@parweld.co.uk...