Severity
Critical
Serviceable
Automatically notify support
User Action
Complete the following steps:
1. User should clear system event log.
• 04 : EvtLogDisabled: Event Logging Disabled sensor, system event log almost full was asserted
Warning is asserted when system event log is at least 75% full.
Severity
Warning
Serviceable
Automatically notify support
User Action
1. User should be aware that system event log is almost full. No action needed.
• 10 : FAN_Tach_1A: Fan sensor, failure event was asserted, reading value : %RPM (Threshold :
1472RPM)
Asserted when Fan tach reading is below threshold RPM.
Severity
Critical
Serviceable
Automatically notify support
User Action
Complete the following steps:
1. If error is not de-asserted after several minutes, check all ten fans are installed.
2. Reseat fan module one or two times. If error still persist, replace fan module.
• 11 : FAN_Tach_1B: Fan sensor, failure event was asserted, reading value : %RPM (Threshold :
1472RPM)
Asserted when Fan tach reading is below threshold RPM.
Severity
Critical
Serviceable
Automatically notify support
User Action
Complete the following steps:
1. If error is not de-asserted after several minutes, check all ten fans are installed.
2. Reseat fan module one or two times. If error still persist, replace fan module.
• 12 : FAN_Tach_2A: Fan sensor, failure event was asserted, reading value : %RPM (Threshold :
1472RPM)
210
ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Messages and Codes Reference