Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0029I: The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM.
[arg2]
Severity: Info
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU
0123456"
User Action:
Information only; no action is required.
• FQXSFMA0030I: A correctable memory error has been detected on DIMM [arg1]. [arg2]
Severity: Info
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU
0123456"
User Action:
Information only; no action is required.
• FQXSFMA0030K: Intel Optane DCPMM [arg1] Percentage Remaining is less than [arg2]% and still
functioning.
Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: Percentage Remaining Threshold
User Action:
Complete the following steps:
1. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
a. Run DCPMM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
• FQXSFMA0031K: Intel Optane DCPMM [arg1] has reached 1% remaining spares block and still
functioning.
Severity: Warning
Parameters:
[arg1]: Dimm Silk Label, 1-based
User Action:
Complete the following steps:
1. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
a. Run DCPMM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
3. Check if the DCPMM meets warranty terms.
.
163
Chapter 3
UEFI events