Operation

System Protection

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner's Manual - Rev14
the energy consumption state (see the Fault and Troubleshooting section for complete
details):
Display- Display State
TURBINE FAULT
GFI
TURBINE FAULT
NO WIND SPEED
TURBINE FAULT
TURBINE OVER CURRENT
TURBINE FAULT
TURBINE OVER VOLTAGE
TURBINE FAULT
NO TURBINE
TURBINE FAULT
LOW BATT
TURBINE FAULT
HIGH BATT
TURBINE FAULT
OVER TEMP
TURBINE FAULT
CHARGE OVER CURRENT
TURBINE FAULT
INVERTER NO OUTPUT
TURBINE FAULT
INVERTER OVER
CURRENT
Figure 4.3
Turbine Fault Stop States
Turbine User Stop State
The turbine will enter its User Stop state if the user engages the manual stop
command in the technician's menu accessible via the SMARTBOX™ Controller.
the
SMARTBOX™ Controller
While in user stop mode, no A/C will be produced so the inverter is shut off and the
transfer switch is switched back to the grid. The
placed in run mode before a charge cycle can start again.
Display - Stopped State
TURBINE STOPPED
PRESS ANY KEY
Cool Down
The turbine will shut off and begin cool down if the charger reaches or exceeds a
temperature of 125°c or/and the enclosure reaches or exceeds a temperature of 60°c.
The turbine will resume working after the charger temperature drops below 70°c and/
or the enclosure temperature drops below 45°c.
Over Wind Speed
The turbine will turn off when wind speed reaches 42mph or higher. It will resume
working after the wind speed drops to 35mph or lower.
Get other manuals https://www.bkmanuals.com
Description
Turbine is stopped and contains a GFI fault.
Voltage sensed but Anemometer not sensing wind
speed.
Turbine is stopped and contains an over current fault.
Turbine is stopped and contains an over temperature
fault.
Anemometer is sensing wind speed but there is no
voltage sensed.
Turbine is stopped and contains a low battery fault.
Turbine is stopped and contains a high battery fault.
Turbine is stopped and contains an over temperature
fault.
Turbine is stopped and contains an over current fault.
See Figure 4.4
See Figure 4.4
is in user mode, the turbine is immediately stopped.
SMARTBOX™ Controller
Description
Turbine is stopped with no faults. Back light is off with
no information scroll.
30
When
must be