Intelligent Terminal Functions
NOTE: Marking [  ],[  ],[
 : Configuration changes are possible during operation.
: You cannot change the parameters during operation.
*
1: In case of (b031) soft lock selections"10", parameter changing during operation is
possible.
F u n c .
N a m e
C o d e
C001
Input [1] function
Input [2] function
C002
Input [3] function
C003
[GS1 assignable]
C004
Input [4] function
[GS2 assignable]
Input [5] function
C005
[PTC assignable]
C006
Input [6] function
Input [7] function
C007
Input [1] active state
C011
C012
Input [2] active state
C013
Input [3] active state
Input [4] active state
C014
Input [5] active state
C015
C016
Input [6] active state
C017
Input [7] active state
Output [11] function
C021
[EDM assignable]
Output [12] function
C022
C026
Alarm relay function
*
1 ],in the table show following meaning.
" C " F u n c t i o n
D e s c r i p t i o n
Select input terminal [1] function,
69 options (see next section)
Select input terminal [2] function,
69 options (see next section)
Select input terminal [3] function,
69 options (see next section)
Select input terminal [4] function,
69 options (see next section)
Select input terminal [5] function,
69 options (see next section)
Select input terminal [6] function,
69 options (see next section)
Select input terminal [7] function,
69 options (see next section)
Select logic conversion, two option
codes:
00normally open [NO]
01normally closed [NC]
49 programmable functions
available for logic (discrete) outputs
(see next section)
49 programmable functions
available for logic (discrete) outputs
(see next section)
68
D e f a u l ts
Run
Mode
I n i t i a l
Edit
d a ta
00
*
1
[FW]
01
*
1
[RV]
02
*
1
[CF1]
03
*
1
[CF2]
09
*
1
[2CH]
18
*
1
[RS]
13
*
1
[USP]
*
1
00
*
1
00
*
1
00
*
1
00
*
1
00
*
1
00
*
1
00
01
*
1
[FA1]
00
*
1
[RUN]
05
*
1
[AL]
U n i ts