Log collection
Hide thumbs Also See for CR210H:

Advertisement

The server is in maintenance mode when the ERROR LED is blinking.
(If the management interface is connected to LAN, it cannot be set to the maintenance mode.)
The factory default settings of the network of the management interface are as follows.
IP address
Subnet mask
Default gateway
DHCP
In the maintenance mode, ERROR LED is blinking.
When one of the following conditions is satisfied, the maintenance mode is canceled.
- In the maintenance mode, the FUNCTION BUTTON is pressed for 10 seconds or more until the ERROR LED
stops blinking.
- The maintenance mode continues for about 30 minutes.
When the maintenance mode is canceled, ERROR LED returns to the original status.
Note that the maintenance mode is not canceled by rebooting the system, turning the system off, or disconnecting
the AC power supply.
3. The mainenance operator connects the PC for maintenance to the management interface connector with a LAN
cross cable.
4. Launch the browser of the administrative system console terminal.
5. Enter "http://192.168.0.1" in the address.
6. When the connection is successfully established, the following login screen is displayed in the browser.
Log in using "user01" as [Username] and "pass01" as [Password].
7. Select the [Logs] tab, and press the [Download Logs] button to save the logs collected by BMC.
8. Save the file and upload to TUF.
https://tuf.hitachivantara.com/upload.php
9. Press the [Logout] button in the upper-right of the screen to log out from Web Console.
If the user does not log out and closes the browser, the status that the user logs in continues until the user is
automatically logged out in about 30 minutes.
Therefore, each time the user closes the browser without log out, a new user cannot log in until 30 minutes has
elapsed.
10. Remove the LAN cross-over cable from the management interface connector.
11. Keep pressing the Function switch for 10 seconds or more to cancel the maintenance mode. Check that ERROR
LED is not blinking.
When the maintenance mode is canceled, ERROR LED returns to the original status.
When one of the following conditions is satisfied, the maintenance mode is canceled.
- In the maintenance mode, the Function switch is pressed for 10 seconds or more.
- The maintenance mode continues for about 30 minutes.
Note that the maintenance mode is not canceled by rebooting the system, turning the system off, or disconnecting
the AC power supply.
12. If customer's LAN cable was connected to the management interface connector before, ask the customer to
reconnect the cable. ask the customer to reconnect the cable, ask the customer to reconnect the cable.
https://knowledge.hitachivantara.com/Support_Information/Data_Collection/Servers/CR210H__CR220H_Log_Collection
: 192.168.0.1
: 255.255.255.0
: Not set
: disabled
Updated: Fri, 19 May 2023 00:38:22 GMT