Sony Tektronix VX4792 User Manual page 159

Arbitrary waveform generator
Table of Contents

Advertisement

Command Descriptions
TRIGger:LEVel (?)
Group
Related Commands
Syntax
Arguments
Examples
3-76
The TRIGger:LEVel command sets the level on the external trigger at which the
trigger event is generated. The TRIGger:LEVel? query returns the level currently
set.
MODE
TRIGger:IMPedance, TRIGger:POLarity, TRIGger:SLOPe
TRIGger:LEVel <unit>
TRIGger:LEVel?
:
TRIGger
<Level>::=<NR2>[<unit>]
where <unit>::={V | mV} with a range of –5.0 V to 5.0 V, in 0.1 V steps.
:TRIGGER:LEVEL 200mV
sets the level to 200 mV.
<Space>
LEVel
<unit>
?