Mode Switch (SW3)
Two DIP switches, labeled SW3, can be used to change the RAEPoint's mode of operation (Host,
Remote, or Router). The RAEPoint's mode was set at the factory, but if you need to reconfigure it,
set the switches as follows:
Switch 1
On
On
Off
Off
Off
Factory settings are indicated by the RAEPoint's serial number:
F081 RAEPoint Remote
l
F082 RAEPoint Router
l
F083 RAEPoint Host
l
F087 MeshGuard PID
l
F088 MeshGuard Flame
l
F081L RAEPoint Remote LoRa
l
F082L RAEPoint Router LoRa
l
Note: After you change the settings on the two DIP switches, press the Reset button (labeled S4).
Honeywell® RAEPoint |
Switch 2
On
Off
On
Off
Off
User Manual
Mode
RAEPoint Host
RAEPoint Remote
RAEPoint Router
MeshGuard
PID/Flame
Factory Setting*