Certification
CCoE
Specific Conditions of Use:
The nonmetallic enclosure parts of this equipment may become a
n
spark ignition hazard in the presence of static electricity. The
enclosure shall be cleaned only with a damp cloth, and the
equipment shall be mounted to avoid building static electric
charge from non-conductive process flow, strong air currents, or
other potential charging through friction.
Honeywell Versatilis Signal Scout (ED) - Model 50187700-100,
n
detects flammable gas, however, is not intended to provide an
indication, alarm, or other output function; purpose of which is to
indicate potential hazard and initiate automatic or manual
protective action(s).
The aluminum enclosure may be capable of producing incendive
n
sparks when impacted. This equipment must be mounted and/or
physically guarded such that it is not subjected to impact or
friction.
WARNING: DO NOT REPLACE BATTERY WHEN AN EXPLOSIVE
ENVIRONMENT IS PRESENT.
USE ONLY "ER34615C BATTERY FROM EVE Energy Co., Ltd".
Standards
ANSI/UL 913-2019 Eighth
Edition
ANSI/UL 60079-0-2020
Seventh Edition
ANSI/UL 60079-11-2018 Sixth
Edition
IS/IEC 60079-0: 2017
IS/IEC 60079-11: 2011
Approval/
Rating
to +70°C
Ex ia IIB T4
Ga
Tamb: -40°C
to +70°C