Section 3: System Architecture - Honeywell Galaxy 2 Series Installation Manual

Hide thumbs Also See for Galaxy 2 Series:
Table of Contents

Advertisement

Galaxy 2 Series Installation Manual

SECTION 3: SYSTEM ARCHITECTURE

Trigger
Header
Serial Port to PC
RS485 BUS
Note: A maximum of 4 keypads
(including keyprox) can be
connected to the RS485 line.
4 outputs
8 zones
OR
4 outputs
8 zones
12-way ribbon cable
Galaxy 2-44
PCB
4 outputs
12 on-board zones
Maximum cable length
from panel to last module
on line is 1km
Mk7 LCD
GALAXY 44 V1.0
09:51
01/08/04
Keypad/Keyprox
A
1
2
3
(4)
B
4
5
6
8
9
ent
7
*
0
#
esc
RIO (4)
C072
Power Unit (4) P025
or
Power RIO (4) P026
Twisted pair screened cable
Belden 8723 equivalent.
Daisy chain configuration only.
RF Portal (2)
Figure 1. Galaxy 2 Series System Configuration
Architecture
Phone line
ECP BUS (2
44+ only)
Maximum cable length
from panel to last module
on line is 100m
Standard 4-core cable
spurred or T wired
TOTAL
MODULE
QTY
Keypads
4
Keyprox
4
Expanders*
4 on RS485
or
3 on ECP
RF Receivers
2
PSU Control/RIO
4
GSM (2-44+ only)
1
2-way Voice (2-44+ only
1
* Only the first expander can be used on the 2-20
5
External
Communicator
6160 keypad (4)
(optionally with
built-in
receiver/keyprox)
Note: maximum of
2 receivers/keyproxes
5800 RF
receiver (2)
ECP zone expander
8 zone, 4 output (3)
ADDRESSES
ECP
RS485 PLUG-ON
AVAILABLE
0,1, 2, 3
4
4
0,1, 2, 3
2
2
2, 3, 4, 5
3
4
4, 5
2
2
2, 3, 4, 5
-
4
-
-
-
-
-
-
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 2-20Galaxy 2-44+

Table of Contents