On-The-Fly Marking: Single Trigger - Panasonic LP-RF Series Setup & Maintenance Manual

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

4-6-5 On-the-fly marking: Single trigger

SHUTTER OPEN OUT
(No.39)
READY OUT (Y5)
TRIGGER IN (X5)
PROCESSING OUT (Y10)
LASING OUT (No.40)
PROCESSING END OUT
(Y11)
Item
Time
T1
T2
2ms or more
T3
T4
2 to 510ms
T5
• If the counter is reset during on-the-fly marking operation, READY OUT (Y5) turns off momentary and there is a case
that the next marking could not be executed due to Warning E751.
112
ON (Open)
OFF (Close)
T1
ON
OFF
ON
T2
OFF
ON
OFF
ON
OFF
ON
OFF
Remarks
Time for marking data creation. It varies depending on the quantity of the setting data.
Keep the ON status for 2ms or more.
Time from when TRIGGER IN (X5) is turned on till when the work piece comes to the
preset marking position.
This is the output to notify that the marking trigger processing completed normally. This is
One-shot output. Set the output time on System settings screen. There is a small margin of
error for the setting value.
Time for marking data creation.
When the next marking data is not ready during the marking operation, this is the rest time
for data creation.
When the next marking data is ready during the marking operation, this takes less than
1ms.
T5
T3
T4
ME-LPRF-SM-11
T5
T2
T3
T4

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-rf200p

Table of Contents