Motorola APEX1000 Installation And Operation Manual page 309

All-purpose edge qam
Table of Contents

Advertisement

Condition
Invalid Init Data
Invalid configuration data on
initialization
Occurs only at APEX bootup
REM1000 Comm
Fault
REM1000 Fault
Port
Failover/Switchback
APEX RF Port
Mismatch
ECMG Channel
Appendix B • Alarms Window Field Definitions
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
Description
RF Redundancy Alarms
REM Communication Fault
Major when experiencing
an REM communication
fault
REM Fault
Major when error received
from REM or REM is
reporting incorrect switch
configuration
QAM RF Redundancy
Failover Alarm
Major when the backup
QAM RF Port status is
active
Occurs when a primary
QAM RF Port has failed
over to the backup RF Port
or the user has forced a
primary to the backup
QAM RF Redundancy
Mismatch Alarm
Warning when channels
could be lost on QAM RF
Fail Over to backup or on
Switch Back to primary
SimulCrypt Alarms
Minor when Active ECMG
Channel is not setup but a
Backup ECMG Channel is
configured and setup
Major when both Active
and Backup ECMG
Channels are not setup
Data Included in
Event or Alarm
Alarm or Event
(Severity Level)
Trap
Alarm
None
Warning
Alarm
N/A
Major
Alarm
Major
Alarm
Major
Alarm
Warning
Alarms
Event generated
identifying the
Minor
Impacted ECMG
Major
channel
B
Notes
1. Indicates that the APEX
is not properly configured
2. Can be disabled
3. Can be cleared
4. Overall alarm - 1 alarm
for all invalid data
1. Can be disabled
2. Clears when REM
connection is restored
1. Can be disabled
2. Clears when REM
errors clear
1. Clears when the backup
QAM RF Port status
returns to 'standby'
2. Can be disabled
1. Clears when mismatch
condition is corrected
2. Can be disabled
1. Can be disabled
2. Clears automatically
when all configured
ECMG Channels are setup
or if Channel is Disabled
by user
3. Overall alarm – 1 alarm
for all ECMG channels
291