Download Print this page

[Read Mode Test]; Drive Status Display; Sequential Seek Test; Random Seek Test - Sharp UP-5900 Service Manual

Advertisement

[READ MODE TEST]

1) DRIVE STATUS DISPLAY

1 Checking content
The hard disk drive standard values (Memory capacity, Number of
cylinders. Number of heads, and Number of sectors) are displayed.
2 Display
Drive Status display
hard disk drive information
Drive Type
: xxxxxx
Capacity
: xxxxMB
Cylinder Number
: xxx
Head number
: xx
Sector number
: xx
Press any key to exit.
Drive type:
Hard disk drive name
Capacity:
Hard disk memory capacity
Cylinder number:
Max. cylinder number
Head number:
Max. head number
Sector number:
Max. sector number
3 Terminating method
Press any key to terminate the test and return to the menu screen in
the previous (1).

2) SEQUENTIAL SEEK TEST

[Test conditions setting]
• Cylinder Range [0 ~ inmost cylinder]
The cylinder range to be tested is set.
• Retry Count [0 ~ 4]
Retry count in case of an error is set.
• Error Stop/Continue/1 Pass
Selection is made among Error Stop/Continue/1 Pass in case of an
error.
• Test Start ? [Yes/No]
Selection is made to execute the test or not.
1 Checking content
In the cylinder range set above, the sequential seek is executed for
every 1 track. When the seek test in the set range is completed (in
the direction of 0 3 inmost cylinder), it is counted as 1 pass. In case
of an error during the above test, a retry is repeated up to the set
number of retries. Every time an error occurs by executing retry up
to the retry number and error logging is performed. Logging is made
for HD and DRAM.
When an "Error stop" is set in the test conditions setting, and an
error occurs during the above test, the error display is made and the
test is stopped. Press the space bar to resume the test.
When "Continue" is set, even if an error occurs, the error display is
made but the test is not stopped.
When "1 Pass" is set, a series of tests is made only once and the
test is stopped.
2 Display
Sequential Seek test execution screen
Sequential Seek test
@Cylinder range ?
@Retry count ?
@[Errorstop continue 1pass]
@Test Start ? [Yes No]
Select the desired items at the position of @. (@ is not displayed on
the screen.)
On the above screen, when the pass count is counted up (when the
point is counted up to the upper limit set in the cylinder range setting,
the pass count is counted up by 1.), and if the error counter of all error
items are not counted up (remaining as 00000), the test is OK.
When the space bar is pressed during the test, the test is inter-
rupted.
When the space bar is pressed during interruption of the test, the
test is started.
3 Terminating method
Press the Esc key during execution of the test or during interruption of
the test to terminate the test and return to the above menu screen.

3) RANDOM SEEK TEST

[Test condition setting]
Same as the above sequential read.
However, execution of the test by 1 Pass means execution of random
seek through the set cylinder range.
1 Checking content
The random seek is executed for every one track in the cylinder
range set previously.
When the seek test is completed in the set range, it is counted as 1
pass.
In case of an error during the above test, a retry is repeated up to
the set number of retries. Every time an error occurs a retry is per-
formed up to the set number of retries, and error logging is made.
Logging is made for HD and DRAM.
When the "Error Stop" is set in the test condition setting, and an
error occurs during the above test.
The error display is shown and the test is interrupted. Press the
space key to resume the test.
When the "Continue" is set, even if an error occurs, the error display
is made but the test is not stopped.
When "1 Pass" is set, a series of tests is made only once and the
test is stopped.
2 Display
Same as the above sequential read, however the following contents
are different.
The test Point is changed at random in the range of 000 ~ XXX (cyl-
inder range set value).
Each point is tested once, and the pass count is added by one with
XXX times.
3 Terminating method
Press the Esc key during execution of the test or during interruption of
the test to terminate the test and return to the above menu screen.
UP-5900VS DIAGNOSTICS SPECIFICATIONS
4 – 11
[000
XXX] = 000-XXX
(XXX is displayed by checking the
inmost cylinder.)
[0
4] = 0
Pass count = XXXXX
Test Point = CCC (Cylinder)
ESC : Exit SPACE : Stop or Start
Error Kinds
Drive not ready XXXX
Bad controller XXXX
Compare error XXXX
Details of error are displayed.

Advertisement

loading