7. Disconnect the gray hose from the right side of the steam generator and
take off its hose clip (Figure 035-13, Item 1).
8. Remove the two T20 screws securing the drain valve assembly to the
steam generator mounting bracket (Figure 035-13, Item 2); separate the
drain valve assembly from the bracket.
1

Figure 035-13: Drain Valve Removal

9. Pull the gray hose down and out through the center of the drain valve.
10. Disconnect the drain valve from the power electronic (the other half of the
8-pin wiring harness goes to the air flap motor, so also disconnect the
electrical connection from the air flap motor).
4.7

Terminal Block Removal

1. Remove the appliance from its housing unit; see Section 010-4.1.
2. Disconnect the appliance from the power supply.
3. Remove the lid; see Section 010-4.2.
4. Remove the rear/left side panel; refer to Section 010-4.4.
5. Remove the cable duct; see Section 010-4.6.
6. Loosen the three Phillips screws securing the power leads to the terminal
block. See circles, Figure 035-14. Release the power leads from the
terminal block.
7. Remove the two T20 screws securing the terminal block to the rear wall
of the appliance. See arrows, Figure 035-14.
8. Remove the terminal block from the appliance.