Fascia Panel/Control Electronic Assembly Removal; Table 060-6: Service Mode Functions - Miele DGC 6 Series Technical Information

Table of Contents

Advertisement

Technical Information
Submenu
Switch status
Operating hours
(total)
Operation
Exit

Table 060-6: Service Mode Functions

1
Always operate the steam generator heater elements with water in the machine.
2
Sensor temperature will be displayed in the units set in the Settings menu (see Section
060-4.1).
Go back, quit:
Go back: Press the Back touchpad.
Quit: Press the  touchpad.
4.4

Fascia Panel/Control Electronic Assembly Removal

1. Pull the machine forward by approximately 4 inches or refer to Section
010-4.1.
Warning!
Ensure that the appliance cannot tip.
2. Pull the lift panel all the way out.
Function/Description
B3-18 (water tank sensor).
Insert or remove the water
tank (the tank on the right).
B3-19 (condensate tank
sensor). Install/Remove the
condensate tank.
B1-2 (drain pump reed
switch)
M28 (air flap)
S60 (lift panel position
switch). Open or close the
fascia manually or by
pressing the Lift Panel
button.
M29 (pinch valve)
The total machine operating hours figure is displayed.
Display
Display backlight
Buzzer/Loudspeaker
(Touch) Sensors
Quit service mode?
116
Option
1: Switch closed. Water tank is
installed.
0: Switch open. Water tank is not
installed.
1: Switch closed. Condensate tank is
installed.
0: Switch open. Condensate tank is not
installed.
1: Switch closed. Pump activated.
0: Switch open. Pump not activated.
1: Switch closed.
0: Switch open.
1: Lift panel is out and up or all the way
in.
0: Lift panel is straight out.
1: Pinch valve closed.
0: Pinch valve open.
The display flashes white and the
sensors next to the display flash yellow.
Backlight test is displayed and the
display changes from dark to light.
The buzzer is activated.
A sensor test is carried out where
different values are displayed when the
various touchpad sensors are activated.
Yes/No