More than superior ventilation
Features
Superior ventilation: 7900 SmartVent
Volume Mode, pressure
Volume Mode, Pressure Control Mode, Pressure Support
(PSVPro
®
), Synchronized Intermittent Mandatory
Ventilation (SIMV), electronic PEEP
Tidal volume compensation
One motion from mechanical to manual mode
Two key presses to total standby: end case
Cardiac bypass case mode
Open systems architecture
Lower overall height
User configurable drawers/shelving
Innovative patient breathing system
Eight machine hoses/cables integrated
"No tools" disassembly of components
Autoclavable and latex-free
Responsive location of common gas outlet
Improved low flow/reduced life cycle costs
Aestiva
®
Two vaporizer configuration
Aestiva/5
Three vaporizer configuration
Fresh gas flow compensation—automatically
Smooth, faster acting fresh gas flow control
Minimum O
flow of 50 mL
2
Dual air flow tube for low flow
Two scheduled maintenance checks per year
/5

Advertisement

Table of Contents
loading

Summary of Contents for GE Aestiva/5

  • Page 1 GE Healthcare Aestiva/5 anesthesia machine Aestiva ® Two vaporizer configuration More than superior ventilation Features Superior ventilation: 7900 SmartVent ™ • Volume Mode, pressure • Volume Mode, Pressure Control Mode, Pressure Support (PSVPro ® ), Synchronized Intermittent Mandatory Ventilation (SIMV), electronic PEEP •...
  • Page 2: Physical Specifications

    Physical Specifications Dimensions Top drawer (1 standard)—locking (internal dimensions) Height: 10.5 cm/4.1 in 2 vaporizer 3 vaporizer configuration configuration Width: 38.5 cm/15.2 in Height: 135.8 cm/53.4 in 135.8 cm/53.4 in Depth: 26 cm/10.2 in Width: 75 cm/29.5 in 93 cm/36.6 in Lower drawers (optional)* Depth: 83 cm/32.7 in...
  • Page 3: Ventilator Operating Specifications

    Absorber arms Ventilator (V ) parameter ranges Tidal volume range: 20 to 1500 mL (Volume Adjustable Non-adjustable Control and SIMV modes) Arm length: 30.5 cm/12 in 25.4 cm/10 in 5 to 1500 mL (Pressure Bag arm Control Mode) height: 87 cm/34.3 in 91.5 cm/36 in Incremental settings: 20 to 100 mL...
  • Page 4 Positive End Expiratory Pressure (PEEP) Alarm settings Type: Integrated, electronically Tidal volume (V Low: OFF, 0 to 1500 mL controlled High: 20 to 1600 mL, OFF Range: OFF, 4 to 30 cm H Minute volume (V Low: OFF, 0 to 10 L/min (increments of 1 cm H High: 0 to 30 L/min, OFF Inspired oxygen (FiO...
  • Page 5: Ventilator Components

    Ventilator components Electrical specifications Flow transducer Current leakage Type: Variable orifice flow sensor 120 V: < 300µA Dimensions: 22 mm OD and 15 mm ID Light package Location: Inspiratory outlet and Task light: 12 V, 3 lamps, type 194, .270A each expiratory inlet Goose neck Optional autoclavable sensor available...
  • Page 6: Pneumatic Specifications

    Pneumatic specifications Flowmeters ranges: Two tubes: 0.05 to 0.95 Internal common gas outlet L/min and 1 to 15 L/min Connector: ISO 22 mm OD and 15 mm ID Minimum O flow: 50 mL/min ±25 mL Auxiliary common gas outlet (optional) O ranges: Two tubes: 0 to 0.95 Connector:...
  • Page 7: Environmental Specifications

    Environmental specifications System operation Temperature: 10° to 40°C/50° to 104°F Humidity: 15 to 95% relative humidity (non-condensing) Altitude: –440 to 3565 m/500 to 800 mmHg System storage Temperature: –25° to 65°C/–13° to 149°F Humidity: 10 to 100% relative humidity (including condensing) Altitude: –440 to 5860 m/375 to 800 mmHg Oxygen cell...