Bosch Rexroth AG

Standards

Operating voltage AC/DC
Operating current AC/DC
Max. switching capacity
B10d value RAFIX 22 FS
Tab. 7-4: Technical data, E-STOP button
For information on the standards, please refer to
10.
8 Standards

8.1 Standards used

Standard
EN 61000-6-4
EN 61000-6-2
EN 61558-2-6
EN 61131-2
ISO 13850
EN 60664-1
EN 60529
EN 60068-2-6
EN 60068-2-27
EN 60721-3-1 to 3
UL 508
Tab. 8-1: Standards used
E-STOP button - Standards
The E-STOP button is identified as safety component according to machinery di-
rective 2006/42/EC (annex V-10, E-STOP devices) by the vendor. The compliance
with the directive is proven by adherence to the following European standards:
IEC 60204-1 (Safety of machinery - Electrical equipment of machines)
10/41
Embedded Terminals with Profibus DP
42 V
100 mA
250 mW
Electrics:
B10d = 5,000,000 (acc. to the manufacturer)
Assumption: B10d = 5 × B10d
Exclusion of failure at < 6050 cycles
Mechanics:
B10d = 250,000 (acc. to the manufacturer)
Assumption: B10d = 5 × B10d
Exclusion of failure at < 6050 cycles
Meaning
Generic standards - Emission standard (industrial environments)
Generic standards – Noise immunity (industrial environments)
Transformer for 24 V power supply unit, safe separation
24 V current supply requirements
Safety of machinery, E-STOP - principles for design
Overvoltage category II
Degrees of protection (including housings and installation com-
partments)
Vibration test
Shock test
Classification of environmental conditions
Industrial Control Equipment
chapter 8 "Standards" on page