Process 15-2 Adding a Redundant Site Controller
1
2
3
4
5
6
7
8
6802800U74-N September 2009
When adding an additional (redundant) Site Controller there will be some service
downtime while making physical modifications.
Back up the Site Controller configuration of the existing Site Controller, See
- Configuration Backup," on page
This assumes that the existing Site Controller is properly configured and in service.
Add second Site Controller, see
Restore the Site Controller Software on the second Site Controller, see
Restoring the Site Controller Software," on page
Configure E1 Links on the second Site Controller, see
E1 Links," on page
8-29.
Configure CAN Bus on the second Site Controller, see
page
8-33.
Load Ki's into MTS. See
Check the MTS post-restoration checks. See
on page
8-39.
When adding a second Site Controller it will automatically become standby meaning
that performance of Site Controller post-restoration checks will not be possible.
In order to perform a Site Controller Post-restoration check on the second Site
Controller, the first Site Controller needs to be reset allowing the second Site
Controller to become active leading to interruption of service for several seconds.
Configure Redundant Site Controller feature. See
on page 15-29
below.
8-19.
Procedure 15-5
below.
8-23.
"MTS - Loading Ki's Into MTS" on page
"MTS - Site Controller Post-Restoration Checks"
"Configuring Redundant Site Controller"
Process 8-2, "MTS
Process 8-3, "MTS -
Procedure 8-12, "MTS - How to Configure
"MTS - Configuring CAN Bus" on
8-34.
How to Install
15-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4

Table of Contents