Page 3
9. Unplug the rack assembly during lightning storms or when – Do not operate the rack assembly while it is wet or standing unused for long periods of time. in liquid. d&b Z5601.002 Manual 1.2 en...
Z5601.002 D40 Touring rack assembly 18 RU CEE 1.1 Intended use The d&b Z5601.002 D40 Touring rack assembly CEE is intended for large scale mobile sound reinforcement applications. It is designed as a closed and prewired 18 RU system rack providing mains power distribution and connector interfaces for 6 x D40 amplifiers.
Page 6
Dimensions and weight Height x width x depth 1060 x 600 x 780 mm 41.73 x 23.6 x 30.7" Total weight ( 1x DN1 included) 179 kg / 394 lb d&b Z5601.002 Manual 1.2 en...
Make sure both the front and rear doors are opened and pushed into their park positions to provide sufficient cooling. When using the d&b Z5601.002 Touring rack assembly, make sure to provide sufficient space of 0.5 m (1.6 ft) at the front and rear of the touring rack to ensure adequate cooling airflow.
Page 8
▪ Do not stack D12 Touring racks or any other rack assemblies with opposing airflow on top of the Z5601.002 Touring rack. ▪ Z5601.002 and the D12 Touring rack assemblies can be positioned side by side.
Connect only one rack assembly to the mains power outlet of the onsite sub-distribution. Each single-phase mains power line is equipped with a dedicated circuit-breaker (16 A / B-Frame type). The respective circuit-breakers of the onsite mains distribution are still necessary for this purpose. d&b Z5601.002 Manual 1.2 en...
The remaining sockets are intended for the connection of low current devices such as notebooks or additional Ethernet switches. The sockets are equipped with dedicated circuit-breakers on the front panel (16 A / C-Frame type). d&b Z5601.002 Manual 1.2 en...
Each connector carries the output signals of all four channels of the amplifier with the following pin assignment. 1+/— = Channel A pos. / neg. 2+/— = Channel B pos. / neg. 3+/— = Channel C pos. / neg. 4+/— = Channel D pos. / neg. d&b Z5601.002 Manual 1.2 en...
DN1 when linking entire rack assemblies, as shown in the graphic opposite. It is recommended to link a maximum of up to 6 rack assemblies in this way. I/O panel, rack link example: 2ch Analog audio and Ethernet/OCA d&b Z5601.002 Manual 1.2 en...
ArraySight sender unit, which is integrated in the flying frame for vertical aiming of the entire array. maximum total of 25 W. If the maximum power is exceeded, PoE supply will be shut off. d&b Z5601.002 Manual 1.2 en...
Alle remote settings are set to default. 6.3.3 LED indicators All device states and operating modes are indicated by dedicated multi-colored LEDs. Note: In case of an device error, connect the device to R1 via OCA to obtain further information. d&b Z5601.002 Manual 1.2 en...
No active connection No AVB network No PoE enabled information device connected LED flashing Traffic PoE Error 6.4 Rear panel ETH 1 - ETH 8 The DN1 device provides a RJ45 8-port panel at the rear of the device. d&b Z5601.002 Manual 1.2 en...