3-Wire Connection Using A Strain Relief Cord - Black & Decker BDFH44M Instruction Manual

4.4 cu. ft. electric ventless dryer with heat pump
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
CONNECTING DRYER USING 3-WIRE
CONNECTION:
Use a 3-wire power supply cord with ring terminals and UL listed strain relief. The
3-wire power supply cord, at least 4.92 ft. (1.5 m) long, must have 3 10-gauge solid
copper wires and match a 3-wire receptacle of NEMA Type 10-30R, rated 240V, min
10A.
3-Wire system connections: Using a strain relief cord
1.
Remove the Neutral grounding wire from center terminal block screw of the
dryer, then connect it to the external ground conductor screw and connect the
neutral wire of the power cord to the center terminal block screw.
2.
Remove the two side terminal block screws and connect the other wires to the
outer terminal screws. Be sure to cross the screw through the terminal ring and
tighten the screw.
3.
Tighten the strain relief screws.
4.
Insert the tab of the terminal block cover into your dryer's rear panel slot. Secure
the cover with a screw.
3-Wire
receptacle
(10-30R)