Download Print this page

Honeywell BW Clip Real Time Quick Reference Manual page 4

2 or 3 year h2s, co, o2, so2 single-gas detector

Advertisement

BW Clip Real Time
2 OR 3 YEAR H
S, CO, O
, SO
2
2
Contact Us
Corporate Headquarters
Honeywell
Suite 110 4411-6 Street SE
Calgary, Alberta
Canada, T2G 4E8
Toll-free: 1-800-663-4164
Americas
Honeywell
405 Barclay Blvd.
Lincolnshire, IL
USA 60069
Toll-free: 1-888-749-8878
Europe
Honeywell
Javastrasse 2
8604 Hegnau
Switzerland
Toll-free: 00800-333-222-44
Other
Honeywell
Toll-free: 1-403-248-9226
info@gasmonitors.com
www.honeywellanalytics.com
Warranty Registration
www.honeywellanalytics.com/support/
product-registration
Maximum Operating Life
24-month Detector
2 years after activation, assuming 2 minutes
of alarm time per day.
Note: 24-month H
S and CO detectors that
2
use hibernation may extend the service
period of the detector up to an additional
year. The service life will end once the
detector reaches 24 months of actual
operation. Hibernation provides a maximum
service life of 36 months.
36-month Detector
3 years after activation, assuming 1 minute
of alarm time per day.
Detection Range
H
S
0 to 100 ppm
2
CO
0 to 300 ppm
O
0 to 25% v/v O
2
2
SO
0 to 100 ppm
2
Factory Alarm Setpoints
Low Alarm
High Alarm
H
S
10 ppm
15 ppm
2
CO
35 ppm
200 ppm
O
19.5% v/v O
23.5% v/v O
2
2
SO
5 ppm
10 ppm
2
Use Safety Suite Device Configurator via an
IntelliDoX station to adjust alarm setpoints.
For more information, refer to the operator
manuals for Safety Suite Device Configurator
software and the IntelliDoX automatic test
and calibration station.
Ratings and Certifications
The BW Clip Real Time is in conformity with
the following standards:
UL 913 8th Edition
UL 60079-0:2013,
UL 60079-11:2013
CSA C22.2 No. 157-92:2012,
CSA C22.2 No. 60079-0:2011,
CSA C22.2 No. 60079-11:2014
EN 60079-0:2012 +A11:2013,
EN 60079-11:2012
IEC 60079-0:2011
IEC 60079-11:2011
IEC 60079-26:2014
ABNT NBR IEC 60079-0:2008
ABNT NBR IEC 60079-11:2009
SINGLE-GAS DETECTOR
2
UL
Classified by UL to both US and Canadian
Standards as intrinsically safe for Class
I, Division 1, Group A, B, C, D and Class I,
Zone 0, Group IIC.
ATEX
CE 0539 II 1G
Ex ia IIC T4 Ga IP66/67
DEMKO 14 ATEX 1356
CE
European Conformity
EU Declaration of Conformity
www.honeywellanalytics.com
IECEx
Ex ia IIC T4 Ga IP66/67
IECEx UL 14.0063
INMETRO
Ex ia IIC T4 Ga
DNV 15.0024
KTL
1
15-KA4BO-0306
Specifications
Shelf Life
H
S
One (1) year before activation
2
CO
One (1) year before activation
O
Six (6) months before activation
2
SO
One (1) year before activation
2
Instrument Weight
alligator clip included
92 grams (3.2 ounces)
Instrument Dimensions
alligator clip included
41 x 50 x 87 millimeters
(1.6 x 2.0 x 3.4 inches)
Operating Temperatures
H
S
-40°C to +50°C
2
(-40 °F to +122°F)
CO
-30 °C to +50°C
(-22 °F to +122°F)
O
-20 °C to +50°C
2
(-4 °F to +122°F)
SO
-30 °C to +50°C
2
(-22 °F to +122°F)
Intrinsic Safety Temperature Range
-40 °C to +50 °C (-40 °F to +122 °F)
Internal Vibrating
Operates to -10°C (+14°F)
Operating Humidity
5% to 95% relative humidity
(non-condensing)
Audible Alarm
2
≈ 95 dB at 10 cm (3.9 in)
Visual Alarm
Flashing, wide-angled alarm lens with red
LEDs plus alarm LCD readout
Display
Liquid crystal display (LCD)
Sensor Type
Electrochemical cells
Battery
Lithium, non-replaceable
Ingress Protection
IP 66/67
Alarm Setpoints
Instant low and instant high
Calibration
To ensure accurate calibration, Honeywell
recommends using a premium-grade
calibration gas approved by the National
Institute of Standards and Technology (NIST).
Do not use a gas cylinder beyond its expiry date.
1 honeywell-analytics/products/bw-clip/docu-ments/
certificates/korea-certi ication_bw-clip-15ka-
44bo0306
Honeywell recommends you calibrate the
detector at least once every 180 days depending
on use and sensor exposure to poisons and
contaminants. Calibrate only in a safe area that
is free of hazardous gas.
Recommended Calibration Gas Mixtures
H
S
5 to 50 ppm balance N
2
2
CO
25 to 250 ppm balance N
SO
5 to 70 ppm balance N
2
2
O
5.0 % to 19.0 % v/v O
2
2
Perform the Zero procedure once every
24 hours or when the Automatic Zero
Reminder is displayed.
Intended Use
This product is classified for use in hazardous
atmospheres that are not more than 21% v/v O
Recycling
This instrument contains a lithium battery.
Do not mix with the solid waste stream. Spent
batteries should be disposed of by a qualified
recycler or hazardous materials handler.
a CAUTION
Products may contain materials that are
regulated for transportation under domestic
and international dangerous goods regulations.
Return product in compliance with appropriate
dangerous goods regulations. Contact freight
carrier for further instructions.
Limited Warranty and
Limitation of Liability
Honeywell warrants this product to be free
from defects in material and workmanship
under normal use and service for a period of
two or three years (depending upon detector),
beginning on the date of activation. 24-month
H
S and CO detectors are covered for up to
2
an additional 12 months when hibernation is
used, limited by a total of 24 months of detector
operation. This Warranty is valid only if the
detector is activated by the date on the package.
This warranty extends only to the sale of new
and unused products to the original buyer.
The obligation of the warranty from Honeywell
is limited, at the option of Honeywell, to refund
of the purchase price, repair, or replacement
of a defective product that is returned to a
Honeywell authorized service center within the
warranty period. In no event shall the liability
of Honeywell liability hereunder exceed the
purchase price actually paid by the buyer for
the Product.
This warranty does not include:
fuses, disposable batteries or the routine
replacement of parts due to the normal wear
and tear of the product arising from use;
any product which in the opinion of
Honeywell, has been misused, altered,
neglected or damaged by accident or
abnormal conditions of operation, handling
or use; or
any damage or defects attributable to repair
2
of the product by any person other than
an authorized dealer, or the installation of
unapproved parts on the product.
The obligations set forth in this warranty are
conditional on:
proper storage, installation, calibration,
use, maintenance and compliance with the
product manual instructions and any other
applicable recommendations of Honeywell;
2
the buyer promptly notifying Honeywell of
any defect and, if required, promptly making
the product available for correction. No
goods shall be returned to Honeywell until
receipt by the buyer of shipping instructions
from Honeywell; and
the right of Honeywell to require that the
buyer provide proof of purchase such as the
original invoice, bill of sale or packing slip
to establish that the product is within the
warranty period.
THE BUYER AGREES THAT THIS WARRANTY IS
THE BUYER'S SOLE AND EXCLUSIVE REMEDY
AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE. HONEYWELL
SHALL NOT BE LIABLE FOR ANY SPECIAL,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, INCLUDING LOSS OF
DATA, WHETHER ARISING FROM BREACH OF
WARRANTY OR BASED ON CONTRACT, TORT
OR RELIANCE OR ANY OTHER THEORY.
¿¿¿'
Since some countries or states do not allow
limitation of the term of an implied warranty,
or exclusion or limitation of incidental or
consequential damages, the limitations and
exclusions of this warranty may not apply to
every buyer. If any provision of this warranty
is held invalid or unenforceable by a court of
competent jurisdiction, such holding will not
affect the validity or enforceability of any other
provisions.

Advertisement