4
Assemble Brake band complete [2] and Link plate
complete [3] to Housing set [1].
5
Compress Compression spring 7 [4] and assemble
it to Housing set [1] with 1R003.
Note
Brake operation without Housing R cover causes a
break of the rib of Housing set [1]. Therefore,
assemble Housing R cover in place when brake
operation is carried out.
Tips
 Assemble Compression spring 7 [4] with Link plate
complete [3] bent fully.
 Apply the specified grease to Link plate complete
[3] and Compression spring 7 [4].
6
Assemble Housing R cover [2] to Housing set [1]
with 4x18 Tapping screws [3] (4 pcs).