Extension cords (220v Only)
using extension cords may reduce the life of the
motor. instead, place the machine near a power
source. if you must use an extension cord:
use at least a 10 gauge cord that does not
exceed 50 feet in length.
Ensure that the extension cord contains a
ground wire and plug pin.
phase converter precaution
the power from the manufactured leg may dam-
age electrical components if connected to the
wrong incoming power terminal on your machine.
only connect the manufactured leg to the L3 ter-
minal (see page 59 for identification).
model g0605X/g0606X (mfg. since 11/06)

440v conversion

the model g0606X can be converted for 440v
operation. this conversion job consists of discon-
necting the saw from the power source, rewiring
the motor, switching the transformer fuse from
220v to 440v, and changing the thermal overload
relay from 22 to 11 amps. refer to the wiring dia-
gram and photos on page 60 and 58 for wiring
details.
all wiring changes must be inspected by a quali-
fied electrician before the saw is connected to the
power source. if, at any time during this procedure
you need help, call grizzly tech support at (570)
546-9663.
-13-