Code
FC.04
When the Code is set as 0.0, the communication overtime parameter is invalid.
When the Code is set to a valid value. if the interval time between two communications
exceeds the communication overtime,the system will report"communication faults"(CE).
Generally, set it as invalid; set the parameter in the continuous communication to
monitor the communication state.
Code
FC.05
0:Alarm and coast to stop
1:No alarm and continue to run
2:No alarm and stop according to F1.06(only Communication setup )
3:No alarm and stop according to F1.06
Inverter in communication exception cases can be set by communication error handling
action selection is shielding CE fault, stop or continue to run.
Code
FC.06
When the communication frequency is set, the actual set frequency is equal to the
frequency set by the communication multiplied by this coefficient.
Code
FC.07
This Code can modify the communication command address of the inverter.
0: Default communication address. For details of the relevant communication control
address, see Chapter 8.6.
Name
Communication on timeout delay
Name
Communication on error action
Name
Communication setting factor
Name
Communication address mark
127
Setting Range
0.0(invalid)ÿ 0.1ÿ^100.0S
0 0.0S0
Setting Range
0ÿ^30 10
Setting Range
10.0ÿ^500.0%
0 100.00
Setting Range
0ÿ^10 00