Malfunction recovery times:When inverter selects malfunction recovery,this parameter
will can be used to set malfunction recovery times.If more than the value of frequency
converter fault standby,it will wait for restore.
Malfunction auto-reset interval:Choosing the time interval between failure occurrence
and automatic reset action.
Code
Fb.15
Fb.16
Fb.17
Recording the inverter recently three failure types:
0:No fault
1ÿ^30:30 different kinds of faults,please refer to Chapter 7.
Code
Fb.18
Fb.19
Fb.20
Fb.21
Fb.22
Fb.23
Fb.24
Fb.25
Fb.26
Fb.27
Fb.28
Fb.29
Recording The current fault state of the inverter.
Name
The first two malfunction types
The last malfunction types
Malfunction types
Name
Malfunction running frequency
Malfunction output current
Malfunction bus voltage
Reserved
Reserved
Previous fault output frequency
Previous fault output current
Previous fault bus voltage
First two fault output frequency
First two fault output currents
First two fault bus voltages
GF Protectionÿ
0:Enabledÿ 1:Disabled
124
Setting Range
0ÿ^300 --0
0ÿ^300 --0
0ÿ^300 --0
Setting Range
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
--0 --0
0ÿ^10 00