Craftsman 580.323610 Operator's Manual
Craftsman 580.323610 Operator's Manual

Craftsman 580.323610 Operator's Manual

Ac generator 3600 watt
Hide thumbs Also See for 580.323610:
Table of Contents

Advertisement

Available languages

Available languages

Operator's Manual
AC Generator
3600 Watt
Model No.
580.323610
Generator
Customer Helpline
1 - 8 0 0 - 2 2 2 - 3 1 3 6
HOURS: Mon. - Fri. 8 a.m. to 5 p.m. (CT)
WARNING
Before using this product, read this
manual and follow all Safety Rules
and Operating Instructions.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.craftsman.com
Part No. 198138GS Draft C (05/08/2006)
ADVERTENCIA
Antes de utilizar el producto, lea este
manual y siga todas las Reglas de
Seguridad e Instrucciones de Uso.
• Safety
• Assembly
• Operation
• Maintenance
• Parts
• Español, p. 36

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 580.323610

  • Page 1 Safety Rules manual y siga todas las Reglas de • Español, p. 36 and Operating Instructions. Seguridad e Instrucciones de Uso. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.craftsman.com Part No. 198138GS Draft C (05/08/2006)
  • Page 2: Table Of Contents

    If this generator fails due to a defect in material or workmanship within one year from the date of purchase, return it to any Sears store, other Craftsman outlet, or Sears Parts & Repair Center in the United States for free repair (or replacement if repair proves impossible).
  • Page 3: Safety Rules

    SAFETY RULES This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Read this manual carefully and become DANGER familiar with your generator.
  • Page 4 WARNING WARNING Fuel and its vapors are extremely flammable and explosive. Unintentional sparking can result in fire or Fire or explosion can cause severe burns or electric shock. death. WHEN ADDING OR DRAINING FUEL WHEN ADJUSTING OR MAKING REPAIRS TO YOUR •...
  • Page 5: Features And Controls

    FEATURES AND CONTROLS KNOW YOUR GENERATOR Read the Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Rocker Switch Fuel Tank...
  • Page 6: Assembly

    ASSEMBLY Your Craftsman generator requires some assembly • Pliers and is ready for use only after it has been properly • Safety glasses serviced with the recommended oil and fuel. Install the Wheel Kit as Follows: If you have any problems with the assembly of 1.
  • Page 7 BEFORE STARTING THE Type of Fuel 1. Always use clean, fresh, UNLEADED gasoline GENERATOR with a minimum of 87 octane/87 AKI (91 RON). DO NOT mix oil with fuel. DO NOT modify the Add Engine Oil engine fuel system or carburetor to run on CAUTION! Any attempt to crank or start the engine alternative fuels.
  • Page 8 Fresh Start™ Fuel Cap 3. Remove tab to expose membrane. Adding fuel preserver helps keep fuel fresh and carburetors clean for easier starting, all season long. This new fuel cap automatically drips concentrated fuel preserver into your fuel tank. DANGER Contents are HARMFUL OR FATAL IF IMPORTANT: DO NOT remove the silver foil seal on the opposite side.
  • Page 9: Operation

    OPERATION HOW TO USE YOUR GENERATOR Generator Location If you have any problems operating your generator Generator Clearance after reading the manual, please call the generator helpline at 1-800-222-3136. WARNING System Ground Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire. The generator has a system ground that connects the generator frame components to the ground terminals •...
  • Page 10: Stopping The Engine

    To Start The Engine WARNING Disconnect all electrical loads from the generator. Running engines produce heat. NEVER start or stop engine with electrical devices Temperature of muffler and nearby areas plugged in and turned ON. Follow start instruction steps in numerical order: can reach or exceed 150°F (65°C).
  • Page 11 CORD SETS AND RECEPTACLES Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to CAUTION 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps Receptacles may be marked with rating value (or greater).
  • Page 12 Running generator gives off carbon 40°F [4°C] combined with high humidity), your monoxide, an odorless, colorless, poison gas. Craftsman generator may experience icing of the Breathing carbon monoxide can cause carburetor and/or the crankcase breather system. To nausea, fainting or death.
  • Page 13 DON’T OVERLOAD GENERATOR 4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. Capacity 6. Repeat steps 4 and 5 for each additional load. You must make sure your generator can supply NEVER add more loads than the generator capacity. enough rated (running) and surge (starting) watts for Take special care to consider surge loads in generator the items you will power at the same time.
  • Page 14: Specifications

    SPECIFICATIONS ENGINE TECHNICAL INFORMATION PRODUCT SPECIFICATIONS This is a single cylinder, overhead valve(OHV), air Generator Specifications cooled engine. It is a low emissions engine. Wattage ....3,600 Watts (3.6kW) In the State of California, Model Series 120000 Starting Wattage .
  • Page 15: Maintenance

    MAINTENANCE MAINTENANCE SCHEDULE Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below. MAINTENANCE SCHEDULE FILL IN DATES AS YOU SERVICE DATES COMPLETE REGULAR SERVICE SERVICE DATES Before Every 25 Hours Every 50 Hours Every 100 MAINTENANCE TASK...
  • Page 16 ENGINE MAINTENANCE StatStation™ The StatStation™ displays the nominal load on WARNING generator based on output frequency. It also has a built in maintenance reminder. Unintentional sparking can result in fire or Wattage Monitor electric shock. The LED display will indicate 0-95% nominal load.The display will flash at 90% nominal load and above.
  • Page 17 Changing Engine Oil Checking Oil Level Oil level should be checked prior to each use or at Change the oil after the first 5 hours of operation. least every 5 hours of operation. Keep oil level Change oil every 50 hours thereafter. If you are using maintained.
  • Page 18 Clean/Replace Spark Plug Clean and inspect the spark arrester as follows: 1. To remove muffler heat shield from muffler, remove Change the spark plug every 100 hours of operation four screws that connect guard to muffler bracket. or once each year, whichever comes first. This will help your engine to start easier and run better.
  • Page 19: Storage

    STORAGE GENERAL Change Oil While engine is still warm, drain oil from crankcase. The generator should be started at least once every Refill with recommended grade. See “Changing seven days and allowed to run at least 30 minutes. If Engine Oil” on page 17. this cannot be done and you must store the unit for more than 30 days, use the following information as a Oil Cylinder Bore...
  • Page 20: Troubleshooting

    TROUBLESHOOTING Problem Cause Correction 1. One of the circuit breakers is 1. Reset circuit breaker. open. 2. Fault in generator. 2. Contact Sears service facility. Engine is running, but no AC 3. Poor connection or defective 3. Check and repair. output is available.
  • Page 21: Notes

    NOTES...
  • Page 22 SCHEMATIC CRAFTSMAN 3600 Watt AC Generator 580.323610...
  • Page 23: Schematic/Wiring Diagram

    WIRING DIAGRAM CRAFTSMAN 3600 Watt AC Generator 580.323610...
  • Page 24: Replacement Parts

    PARTS CRAFTSMAN 3600 Watt AC Generator 580.323610 Main Unit — Exploded View...
  • Page 25 CRAFTSMAN 3600 Watt AC Generator 580.323610 Main Unit — Parts List Item Part # Description 198816GS ASSY, Cradle 194150GS KIT, Vibration, Mount, 45° 67989GS NUT, M8 Flange Serrated 186058AGS HOUSING, Engine Adapter ASSY, Alternator (see page 27) NUT, Hex M8 - 1.25 TPHMS, M8 - 1.25 x 35...
  • Page 26 CRAFTSMAN 3600 Watt AC Generator 580.323610 Control Panel — Exploded View and Parts List Item Part # Description 196898GS PANEL, Control 197004GS COVER, Outlet Flip 188890GS COVER, Back Panel 197731GS OUTLET, 120V, 15/20A Dplx 189165GS NUT, 5/32 Pal 197729GS MODULE, Led...
  • Page 27 CRAFTSMAN 3600 Watt AC Generator 580.323610 Alternator — Exploded View & Parts List Item Part # Description 186059GS ADAPTER, Mounting, Alternator 192164GS ROTOR (Includes Item 12) 199047AGS STATOR 186060GS RBC, with O-Ring (p/n 189197GS) 86308JGS HHCS, M6 - 1.0 x 95 SEMS...
  • Page 28 CRAFTSMAN 3600 Watt AC Generator 580.323610 Wheel Kit — Exploded View and Parts List Item Part # Description 196517GS WHEEL 191267NGS AXLE 191265GS E-RING WASHER, 5/8" B1764GS SUPPORT, Wheel Kit 67989GS NUT, M8, Flange Serrated HHCS, M8- 1.25 x 16 * - Items without part numbers are common fasteners and are available at local hardware stores.
  • Page 29 ENGINE, 7.0 HP, Briggs and Stratton, 121012 – Exploded View...
  • Page 30 ENGINE, 7.0 HP, Briggs and Stratton, 121012 – Exploded View...
  • Page 31 ENGINE, 7.0 HP, Briggs and Stratton, 121012 – Exploded View...
  • Page 32 ENGINE, 7.0 HP, Briggs and Stratton, 121012 – Parts List Item Part # Description Item Part # Description 699510 Cylinder Assembly 699598 Housing-Blower 399269 Kit-Bushing/Seal (Magneto Side) 699480 Screw (Blower Housing) 299819 £ Oil Seal (Magneto Side) 693610 Shield-Cylinder 699486 Head-Cylinder 699483 Screw (Cylinder Shield)
  • Page 33 NOTES...
  • Page 34: Emissions System Warranty

    EMISSIONS CONTROL SYSTEM WARRANTY Sears, Roebuck and Co., U.S.A. (Sears), the California Air Resources Board (CARB) and the United States Environmental Protection Agency (U.S.EPA) Emissions Control System Warranty Statement (Owner's Defect Warranty Rights and Obligations) The California Air Resources Board (CARB), U.S. EPA and a.
  • Page 35 Emissions Durability Period and Air Index Emissions Compliance Period On Engine Information On Your Engine Emissions Label Emissions Compliance Label Engines that are certified to meet the California Air After July 1, 2000 certain Sears engines will be certified to Resources Board (CARB) Tier 2 Emission Standards must meet the United States Environmental Protection Agency display information regarding the Emissions Durability Period...
  • Page 36: Español

    Si el generador falla debido a defectos de materiales o mano de obra en el plazo de un año a partir de la fecha de compra, devuélvalo a cualquier almacén Sears, punto de venta de Craftsman o centro de reparación y repuestos de Sears de los Estados Unidos para su reparación gratuita o, en caso de que ésta no sea posible, para su sustitución.
  • Page 37: Reglas De Seguridad

    REGLAS DE SEGURIDAD Este es el simbolo de alerta de seguridad. Es usado para indicarle situaciones con peligros potenciales de lesion para el personal. Siga las instrucciones de todos los mensajes de seguridad que aparecen despues de este simbolo para evitar posibles lesiones o muerte. Lea este manual de manera cuidadosa y PELIGRO familiarícese con su generador.
  • Page 38 ADVERTENCIA ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos. Chispear involuntario puede tener como El fuego o una explosión pueden causar resultado el fuego o el golpe eléctrico. quemaduras severas e inclusive la muerte. CUANDO AÑADA COMBUSTIBLE O VACÍE EL CUANDO AJUSTE O HAGA REPARACIONES A SU DEPÓSITO GENERADOR...
  • Page 39: Conozca Su Generador

    CARACTERÍSTICAS Y CONTROLES CONOZCA SU GENERADOR Lea este manual del operario y las reglas de seguridad antes de operar su generador. Compare las ilustraciones con su generador para familiarizarse con la ubicación de los diferentes controles y ajustes. Conserve este manual para referencias futuras. Interruptor de Marcha/Parado Tanque de Combustible...
  • Page 40: Montaje

    MONTAJE Su generador requiere de ciertos procedimientos de montaje y • Alicates solo estará listo para ser utilizado después de haberle • Gafas de seguridad suministrado servicio con el combustible y aceite recomendados. Instale el juego de ruedas conforme a las instrucciones Si usted tiene problemas con el montaje de su siguientes: generador, por favor llame a la línea de ayuda para...
  • Page 41 ANTES DE DARLE ARRANQUE AL Tipo de combustible Utilice siempre gasolina sin plomo limpia y nueva con GENERADOR un máximo de 87 octanos/87 AKI (91 RON). No mezcle aceite con combustible. No modifique el circuito de Agregar Aceite al Motor combustible ni el carburador para utilizar combustibles alternativos.
  • Page 42 Tapón de Combustible para Mejorar el Arranque Retire la lengüeta para dejar la membrana al descubierto. El uso de conservante de combustible mantiene el combustible en buen estado y limpia los carburadores, lo que facilita el arranque en todas las estaciones del año. El nuevo tapón de combustible gotea automáticamente conservante concentrado en el depósito de combustible.
  • Page 43: Funcionamiento

    FUNCIONAMIENTO COMO USAR SU GENERADOR Ubicación del Generador SI TIENE PROBLEMAS operando su generador después de Espacio Libre Alrededor del Generador leer el manual, por favor llame a la línea de ayuda para ADVERTENCIA generadores al 1-800-222-3136. Tierra del Sistema Los gases y el calor de escape pueden inflamar los materiales combustibles y las estructuras o dañar El generador dispone de una conexión a tierra del sistema...
  • Page 44 Encienda el Motor NOTA: Si el motor arranca después de tirar tres veces del arrancador pero no sigue funcionando, o si la unidad se Desconecte todas las cargas eléctricas del generador. para en funcionamiento, asegúrese de que la unidad está NUNCA arranque o pare el motor cuando haya aparatos en una superficie plana y compruebe que el nivel de aceite eléctricos conectados y en funcionamiento.
  • Page 45 Detener el Motor Desconecte todas las cargas eléctricas de la unidad. NUNCA arranque o detenga el motor con dispositivos eléctricos conectados a él y encendidos. Permita que el motor funcione sin carga durante dos minutos para estabilizar las temperaturas internas de la unidad.
  • Page 46 OPERACIÓN DURANTE UN CLIMA ADVERTENCIA FRÍO Al generador funcionar, se produce monóxido de En ciertas condiciones climáticas (temperaturas inferiores a carbono, un gas inodoro y venenoso. 4º C [40º F] combinadas con un alto nivel de humedad), su El respirar el monóxido de carbono, producirá generador puede experimentar formación de hielo en el náusea, desmayo o la muerte.
  • Page 47 NO SOBRECARGUE GENERADOR Conecte y encienda la próxima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos 4 y 5 para cada carga adicional que Usted debe asegurarse que su generador puede proveer el usted tenga. suficiente vataje calificado (cuando esté...
  • Page 48: Especificaciones

    ESPECIFICACIONES INFORMACIÓN TÉCNICA SOBRE EL ESPECIFICACIONES DEL MOTOR PRODUCTO El motor es de uno cilindros, de válvulas en cabeza (OHV), Especificaciones del Generador refrigerado por aire y de baja emisión. Vataje ......3600 vatios (3.6 kW) En el Estado de California, los motores de la serie 120000 Vataje que Empieza.
  • Page 49: Mantenimiento

    MANTENIMIENTO PROGRAMA DE MANTENIMIENTO Siga los intervalos horarios o de calendario, lo que ocurra primero. Se requiere de servicio con mayor frecuencia cuando opere la unidad en las condiciones adversas descritas a continuación. CALENDARIO DE MANTENIMIENTO INTERVALO DE OPERACIÓN POR HORA ANOTE LAS FECHAS CONFORME CUMPLA CON EL SERVICIO NORMAL FECHAS DE SERVICIO...
  • Page 50 MANTENIMIENTO DEL MOTOR StatStation™ El StatStation™ muestra la carga nominal del generador en ADVERTENCIA función de la frecuencia de salida. También incluye una función de aviso de mantenimiento integrada. Chispear involuntario puede tener como Monitor de potencia resultado el fuego o el golpe eléctrico. El visor de LED indicará...
  • Page 51 Cambio de Aceite del Motor Comprobación del Nivel de Aceite Compruebe el nivel de aceite antes de cada uso o cada Cambie el aceite después de las primeras 5 horas de 5 horas de funcionamiento, como mínimo. Rellene si es operación.
  • Page 52 Reemplace la bujía si los electrodos están picados, Retire los cuatro tornillos que sostienen la pantalla quemados o si la porcelana está rota. Utilice una bujía apagachispas. de repuesto recomendada. Inspeccione la pantalla y reemplácela si está rota, Instale la bujía y aprietela firmemente. perforada o dañada.
  • Page 53: Almacenamiento

    ALMACENAMIENTO GENERALIDADES Cambio de Aceite Con el motor todavía caliente, drene el aceite de la caja del El generador deberá ser encendido al menos una vez cada cigüeñal. Vuelva a llenarla con el grado de aceite siete días y deberá dejarlo funcionar al menos durante recomendado.
  • Page 54: Reparacion De Averias

    DIAGNÓSTICO Y REPARACIÓN DE AVERÍAS Problema Causa Solución Uno de los cotacircuitos está Reajuste el cortacircuito. abierto. Falla en el generador. Póngase en contacto con la Planta de Servicio de Sears. El motor está funcionando pero no existe salida de AC disponible. Mala conexión o juego de cordones Revise y repare.
  • Page 55: Notas

    NOTAS...
  • Page 56 NOTAS...
  • Page 57 NOTAS...
  • Page 58: Garantia Del Sistema De Control De Emisiones

    GARANTIA DEL SISTEMA DE CONTROL DE EMISIONES Sears, Roebuck and Co., U.S.A. (Sears), California Air Resources Board (Consejo de Recursos sobre el Aire de California, CARB, por sus siglas en inglés) y United States Environmental Protection Agency (Agencia de Protección Ambiental de EE.UU.
  • Page 59 Información Sobre el Período de Período de Cumplimiento de la Normativa Durabilidad de las Emisiones y el Índice de Emisiones en la Etiqueta de de Aire en la Etiqueta de Emisiones del Cumplimiento de Emisiones del Motor Motor Desde el 1 de julio de 2000, algunos motores Sears cuentan con la certificación de cumplimiento de la fase 2 de las Los motores con certificación de cumplimiento de la normas sobre emisiones de la United States Environmental...

Table of Contents