Download Print this page

RIDGID K-750R 5/8 Instructions For Installing

Advertisement

Quick Links

Figure 4 – T-411 2", T-413 3" & T-414 4" Cutter: Used for
general cleaning to remove tree roots and
materials clinging to pipe walls.
Machine Assembly
WARNING
To prevent serious injury, proper assembly of the
Connecting/Disconnecting
Keep couplings clean and lubricated. Plunger pin must move freely and fully extend to secure connection.
New style – Plunger pin
Screwdriver required.
Connecting
1
1. Slide the couplings together. If needed, depress plunger
pin.
2. Confirm connection is secure. (plunger pin fully extend-
ed).
Disconnecting
1
2
1. Insert the screwdriver to depress the plunger pin.
2. Push the couplings apart until the male coupling con-
tacts the screwdriver.
3. Remove the screwdriver and push the couplings apart.
Figure 5
5
/
" and
8
2
3a
3b
K-750R
5
/
Drain Cleaner is required. The following proce-
dures should be followed:
Instructions For Mounting Handles and
Belt Guard
Handles – Assemble handles to machine frame and
secure with two (2) belt guard screws.
Belt Guard – Check the belt guard to ensure that it is
" from the drum. Reposition guard if nec-
approximately
1
/
4
essary and tighten bolts (Figure 6) .
Gap between belt guard and drum
WARNING
should not exceed
1
/
between belt and pulley. Do not operate machine with-
out belt guard.
Instructions For Installing Cable
Do not remove bands or staples from cable
CAUTION
shipping carton. Cable is under tension and will whip
causing injury.
3
/
" Drum Machine Cable Couplings
4
Old style – Rotating pin
Screwdriver required.
Connecting
Hash Mark
1. Slide the couplings together.
2. Rotate pin so hash mark is away from end of cable
(towards "L" stamped on coupling). Confirm connection
is secure.
Disconnecting
1. Rotate pin so hash mark is towards end of cable (away
from "L" stamped on coupling).
2. Push the couplings apart.
" Cage Machine
8
" to prevent fingers being caught
2
5

Advertisement

loading

Summary of Contents for RIDGID K-750R 5/8

  • Page 1 K-750R " Cage Machine Drain Cleaner is required. The following proce- dures should be followed: Instructions For Mounting Handles and Belt Guard Handles – Assemble handles to machine frame and Figure 4 – T-411 2″, T-413 3″ & T-414 4″ Cutter: Used for secure with two (2) belt guard screws.
  • Page 2 K-750R " Cage Machine Retrieve end of cable through the center hole of carton and 3. Inspect the power cord, Ground Fault Circuit Inter - remove enough cable to connect with drum pigtail. Connect rupter (GFCI) and plug for damage. If the plug has the male coupling of the cable to the pigtail coupling (see been modified, is missing the grounding prong or if the Figure 5) .