Omega OM-CP-RFCURRENT2000A User Manual page 7

Wireless current data logger
Table of Contents

Advertisement

Quick Start Manual
OM-CP-RFCURRENT2000A General Specifications
Reading Rate 1 reading every second up to 1 reading every 24 hours
Memory 32,256 readings
Memory Wrap Around Yes
Start Modes Immediate Start & Delayed Start
Stop Modes
Real Time Recording The device may be used with PC to monitor and record data in real time
Audible Alarm Functionality 1 beep per second for reading alarm above/below threshold
LED Functionality
Password Protection
Engineering Units
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Battery Type Ultralife 9V lithium battery included; user replaceable
Battery Life Approximately 4 years typical at 15 minute reading rate
Data Format uA, mA, A
Time Accuracy ± 1 minute/month
Computer Interface
Software XP SP3/Vista/Windows 7/Windows 8 (Omega 4 Software only)
Operating Environment -20 °C to +60 °C (-4 °F to +140 °F); 0 to 95% RH non-condensing
Dimensions 3.3" x 3.5" x 0.95" (82.6 mm x 88.9 mm x 24.1 mm) - Data logger only
Enclosure Material ABS Plastic
Approval US (FCC), CA (IC), CE, South Korea (KCC)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should be maintained
between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. The
antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
• Manual through software
• Delayed Stop
• Timed (specific date and time)
User configurable audible, on-screen, email and text (SMS) alarms.
Alarm Delay: A cumulative alarm delay may be set in which the device
Alarm
will activate the alarm (via LED) only when the device has recorded a
user specified time duration of data.
• Green LED blinks every 10 seconds to indicate unit is logging
• Blue LED blinks every 30 seconds to indicate unit is in wireless mode
• Red LED blinks every 1 second to indicate alarm condition
An optional password may be programmed into the device to restrict access
to configuration options. Data may be read out without the password.
Native measurement units can be scaled to display measurement units
of another type. This is useful when monitoring voltage outputs from
different types of sensors such as temperature, CO2, flow rate and more.
USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-
EXT required for wireless operation
Weight 4.1 oz (0.2563 lbs)