Quick Start Manual
OM-CP-RFCURRENT2000A:
by switching the wireless mode to OFF by holding down the Wireless button on the data logger for 5 seconds.
1.
Use the USB Cable, plug the USB end of the cable into an available USB port on the PC.
2.
Plug the opposite end of the cable into the communication port on the OM-CP-RFCURRENT2000A.
3.
Open the Omega Software. Locate and select the OM-CP-RFCURRENT2000A in the Connected
Devices panel.
4.
In the Device tab, click the Properties icon. The Properties screen will display information about the
device including Wireless setting.
Under the Wireless tab, select a desired channel (11-25) that will match with the OM-CP-RFC1000-EXT
5.
Save all changes, disconnect the data logger, and return the device to wireless mode by holding down
the Wireless button for 5 seconds.
Deploying and Activating Devices
1.
Plug the OM-CP-RFC1000-EXT into the USB port on the base station computer. (Additional OM-CP-
RFC1000-EXTs can be used as repeaters to transmit over greater distances)
2.
If using multiple OM-CP-RFC1000-EXTs plug each one into a wall outlet in the desired locations. (If
transmitting over a distance greater than 1000 feet indoors or 4000 feet outdoors or there are walls/obstacles/
corners that need to be maneuvered around, set up additional OM-CP-RFC1000-EXTs as needed.)
3.
Verify that the data loggers are in wireless transmission mode. (See Channel Programming steps above)
On a Windows PC, launch the Omega data logger software program. All active data loggers will be listed
in the software showing that the device(s) are recognized.
To activate the data loggers, click on one to highlight, then click the Claim icon, and then click the Start
4.
icon. Do this for each logger in the list that needs to be activate.
To program the channel on the OM-CP-RFCURRENT2000A data logger, start