Troubleshooting Tips - Omega OM-CP-RFCURRENT2000A User Manual

Wireless current data logger
Table of Contents

Advertisement

Quick Start Manual

Troubleshooting Tips

Why is the wireless data logger not appearing in the software?
If the OM-CP-RFCURRENT2000A doesn't appear in the Connected Devices panel, or an error message is
received while using the OM-CP-RFCURRENT2000A, try the following:
• Check that the OM-CP-RFC1000-EXT is properly connected. For more information, see Troubleshooting
Interface Cable problems (below).
• Ensure that the battery is not discharged. For best voltage accuracy, use a voltage meter connected to the
battery of the device. If possible, try switching the battery with a new OM-CP-BAT103.
• Ensure that no other Omega software is running in the background.
• Ensure that Omega Software is being used.
• Ensure that the Connected Devices panel is large enough to display devices. This can be verified by
positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then
dragging the edge of the panel to resize it. The screen layout may also be reset in the options menu by
selecting File, Options, and scrolling to the bottom.
Troubleshooting Interface Cable problems
Check that the software properly recognizes the connected OM-CP-RFC1000-EXT wireless transceiver.
If the wireless data logger is not appearing in the Connected Devices list, it may be that the OM-CP-RFC1000-
EXT is not properly connected.
1.
In the software, click the File button, then click Options.
2.
In the Options window, click Communications.
3.
The Detected Interfaces box will list all of the available communication interfaces. If the OM-CP-
RFC1000-EXT is listed here, then the software has correctly recognized and is ready to use it.
Check that Windows recognizes the connected OM-CP-RFC1000-EXT wireless transceiver.
If the software does not recognize the OM-CP-RFC1000-EXT, there may be a problem with Windows or the
USB drivers.
1.
In Windows, click Start, right-click Computer and choose Properties or press Windows+Break as a
keyboard shortcut.
2.
Click Device Manager in the left hand column.
3.
Double click Universal Serial Bus Controllers.
4.
Look for an entry for Data logger Interface.
5.
If the entry is present, and there are no warning messages or icons, then windows has correctly
recognized the connected OM-CP-RFC1000-EXT.
6.
If the entry is not present, or has an exclamation point icon next to it, the USB drivers may need to be
installed. These are available on the software flash drive included with the OM-CP-RFC1000-EXT, and
on the Omega website.
Ensure that the USB end of the OM-CP-RFC1000-EXT is securely connected to the computer.
1.
Locate the USB-A plug of the OM-CP-RFC1000-EXT.
2.
If the interface cable is connected to the PC, unplug it. Wait ten seconds.
3.
Reconnect the cable to the PC.
4.
Check to make sure that the red LED is lit, indicating a successful connection.
Questions?
For more details and instructions, please refer to the rest of this guide, visit us online at www.omega.com
or contact us for support at 1 (800) 872-9436.