Cmos Battery; Battery Pack - Bosch Rexroth lndraControl VPB 40.1 Project Planning Manual

Control cabinet pc
Table of Contents

Advertisement

DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
8.3

CMOS Battery

8.4

Battery Pack

Connection battery pack
2. The new hard disk parameters are automatically identified by the system.
If the operating system does not boot automatically, the power supply is
to be interrupted for at least 10 seconds. A restart needs to be carried out
again.
3. After properly booting the PC the user data and the operating system set‐
tings for the normal mode have to be restored.
The battery used for buffering the RAM and the clock has a limited service life,
see also
chapter 4.8 "Wear Parts" on page
This lithium battery must not be changed by the user. The battery may only be
exchanged by the Bosch Rexroth Service (see
port" on page
77) or by personnel trained and authorized by the Service.
WARNING
Do not recharge, disassemble, crush, heat above 100°C (212°F) or incinerate.
Dispose of used battery promptly. Keep away from children!
For the uninterruptible power supply of VPB 40.1 an external battery pack for
control cabinet mounting is available.
The battery pack is connected with the 2-pin male connector strip X19 situated
at the connector panel on the upper side of the PC box. For this, use an un‐
shielded cable with line cross-sections of at least 1.5 mm
maximum 3.0 m.
Bosch Rexroth provides ready-made cables with a length of 1.0 m and 3.0 m,
see
chapter 11.2.2 "Battery Pack and cables" on page
VPB 40.1
X19
Fig.8-2:
External battery pack
To connect the external batteries proceed as follows:
1. Select a suitable position for mounting the battery in the control cabinet.
The battery pack should be mounted in a cool place in the control cabinet
because the surrounding air temperature directly influences the service
life of the battery. A required mounting position can be selected (see the
following figures).
Bosch Rexroth AG
Maintenance and Installation
23.
chapter 12 "Service and Sup‐
Warning: Battery safety. Risk of fire, explosion,
and burns.
2
74.
Battery pack
Akku-Pack
49/81
. The cable length is