Bosch REXROTH VSB 40.1 Project Planning Manual

Hide thumbs Also See for REXROTH VSB 40.1:
Table of Contents

Advertisement

Quick Links

8 a.m. - 5 p.m. Sales Available
International: 1-919-443-0207
Toll Free: 1-888-551-3082
All Products from Wake Industrial, LLC, come with:
Sales and Repairs
We specialize in providing
immediate product delivery
when your system goes
down. We have thousands
of
In-Stock
automation
products and offer a full
range of repair options.
Damage Free Delivery
Stay In Touch
Wake Industrial, LLC
1620 Old Apex Road
Cary, NC 27513
Visit Our Website
www.wakeindustrial.com
Fast Shipping
We ship worldwide, offering
any type of shipping method
with all the major logistic
companies such as FedEx,
UPS, DHL, USPS, and a
variety of freight carriers.
All of our products are cleaned, go through quality control and are
shipped using a custom military grade foam to ensure your product
arrives undamaged.
small 1lb
products
regardless of your location.
Wake Industrial is not affiliated
with nor an authorized distributor
or representative of any
manufacturers, brands or
products listed.
sales@wakeindustrial.com
With standards like our 1 year
warranty on ALL products, we
can
customer service experience
than any other company within
our industry.
We have the capability to ship both
and
large
200lb+
International:1-919-443-0207
Email: sales@wakeindustrial.com
Website: www.wakeindustrial.com
Email Us
Quality Guarantee
guarantee
a
automation
parts
Call: 1-888-551-3082
Fax:1-919-267-1705
better

Advertisement

Table of Contents
loading

Summary of Contents for Bosch REXROTH VSB 40.1

  • Page 1 Email Us Visit Our Website 8 a.m. - 5 p.m. Sales Available sales@wakeindustrial.com www.wakeindustrial.com International: 1-919-443-0207 Toll Free: 1-888-551-3082 All Products from Wake Industrial, LLC, come with: Sales and Repairs Fast Shipping Quality Guarantee We ship worldwide, offering We specialize in providing With standards like our 1 year immediate product delivery any type of shipping method...
  • Page 2 Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth VSB 40.1 R911310079 Edition 02 Project Planning Manual...
  • Page 3 First Edition 120-2100-B372-02/EN 04.2008 Second Edition  2005 Bosch Rexroth AG Copyright Copying this document, giving it to others and the use or communication of the contents thereof without express authority, are forbidden. Offenders are liable for the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design (DIN 34-1).
  • Page 4: Table Of Contents

    VSB 40.1 Contents Contents System Representation Brief Description VSB 40.1 ......................1-1 Operating System ......................... 1-1 Commissioning ..........................1-2 Important Directions for Use Appropriate Use..........................2-1 Introduction ..........................2-1 Areas and Use of application....................2-2 Inappropriate Use ......................... 2-2 Safety Instructions for Electric Drives and Controls Introduction ...........................
  • Page 5 Contents VSB 40.1 Mounting with Connector Panel on the Top Side ..............5-4 Mounting the VSB 40.1, Variant LS....................5-5 Mounting with Connector Panel in Forward Direction ............. 5-5 Installation Notes .......................... 5-6 Display and Operating Components Power Button ..........................6-1 Display, Monitor and Keyboard ....................
  • Page 6 VSB 40.1 Contents 10 Disposal and Environmental Protection 10-1 10.1 Disposal ............................10-1 Products..........................10-1 Packaging Materials ......................10-1 10.2 Environmental Protection......................10-1 No Release of Hazardous Substances ................. 10-1 Materials Contained in the Products ..................10-1 Recycling ..........................10-2 11 Ordering Information 11-1 11.1 Type Code Designation VSB40.1....................
  • Page 7 Contents VSB 40.1 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 8: System Representation

    VSB 40.1 System Representation System Representation Brief Description VSB 40.1 The VSB 40.1 is an industrial PC, that represents in combination with a display VDP 16 or VDP 40 a PC-based operator terminal, and that can – depending on the application and configuration – also perform control functions.
  • Page 9: Commissioning

    System Representation VSB 40.1 Commissioning Mount the device properly (for this, see chapter "Dimensions and Installation Notes as of page 5-1). Then, connect the device to the power supply and, if required, to the network. DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 10: Important Directions For Use

    Note: Bosch Rexroth, as manufacturer, is not liable for any damages resulting from inappropriate use. In such cases, the guarantee and the right to payment of damages resulting from inappropriate use are forfeited.
  • Page 11: Areas And Use Of Application

    This includes, for example, operation under water, in the case of extreme temperature fluctuations or extreme maximum temperatures or if • Bosch Rexroth has not specifically released them for that intended purpose. Please note the specifications outlined in the general Safety Instructions...
  • Page 12: Safety Instructions For Electric Drives And Controls

    If you do not have the user documentation for your equipment, contact your local Bosch Rexroth representative to send this documentation immediately to the person or persons responsible for the safe operation of this equipment.
  • Page 13: Hazards By Improper Use

    Safety Instructions for Electric Drives and Controls VSB 40.1 Hazards by Improper Use High voltage and high discharge current! Danger to life or severe bodily harm by electric shock! DANGER Dangerous movements! Danger to life, severe bodily harm or material damage by unintentional motor movements! DANGER High electrical voltage due to wrong...
  • Page 14: General Information

    VSB 40.1 Safety Instructions for Electric Drives and Controls General Information • Bosch Rexroth AG is not liable for damages resulting from failure to observe the warnings provided in this documentation. • Read the operating, maintenance and safety instructions in your language before starting up the machine.
  • Page 15: Protection Against Contact With Electrical Parts

    Safety Instructions for Electric Drives and Controls VSB 40.1 • Operation is only permitted if the national EMC regulations for the application are met. The instructions for installation in accordance with EMC requirements can be found in the documentation "EMC in Drive and Control Systems".
  • Page 16: Protection Against Electric Shock By Protective Low Voltage (Pelv)

    VSB 40.1 Safety Instructions for Electric Drives and Controls To be observed with electrical drive and filter components: High electrical voltage on the housing! High leakage current! Danger to life, danger of injury by electric shock! ⇒ Connect the electrical equipment, the housings of all DANGER electrical units and motors permanently with the safety conductor at the ground points before power is...
  • Page 17: Protection Against Dangerous Movements

    Safety Instructions for Electric Drives and Controls VSB 40.1 Protection Against Dangerous Movements Dangerous movements can be caused by faulty control of the connected motors. Some common examples are: • improper or wrong wiring of cable connections • incorrect operation of the equipment components •...
  • Page 18: Protection Against Magnetic And Electromagnetic Fields During Operation And Mounting

    VSB 40.1 Safety Instructions for Electric Drives and Controls ⇒ Secure vertical axes against falling or dropping after switching off the motor power by, for example: - mechanically securing the vertical axes - adding an external braking/ arrester/ clamping mechanism - ensuring sufficient equilibration of the vertical axes The standard equipment motor brake or an external brake controlled directly by the drive controller are...
  • Page 19: Protection Against Contact With Hot Parts

    Safety Instructions for Electric Drives and Controls VSB 40.1 Protection Against Contact with Hot Parts Housing surfaces could be extremely hot! Danger of injury! Danger of burns! ⇒ Do not touch housing surfaces near sources of heat! Danger of burns! CAUTION ⇒...
  • Page 20: 3.11 Battery Safety

    VSB 40.1 Safety Instructions for Electric Drives and Controls 3.11 Battery Safety Batteries contain reactive chemicals in a solid housing. Inappropriate handling may result in injuries or material damage. Risk of injury by incorrect handling! ⇒ Do not attempt to reactivate discharged batteries by heating or other methods (danger of explosion and cauterization).
  • Page 21 3-10 Safety Instructions for Electric Drives and Controls VSB 40.1 Notes DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 22: Technical Data

    VSB 40.1 Technical Data Technical Data PC Box PC box Type E Processor Celeron with minimum 2 GHz Integrated graphic controller Chip set with maximum 8 MB video memory Random access memory (RAM) 512 MB / 1024 MB Min. 30 GB Hard disk DVD ROM or DVD RW Optional drives...
  • Page 23: Power Supply 115 V / 230 V

    Technical Data VSB 40.1 Power Supply 115 V / 230 V Nominal input voltage: 115 VAC / 230 VAC Input voltage range: 90 ... 264 VAC Input current: 2.5 A for nominal voltage 230 VAC 5.0 A for nominal voltage 115 VAC Inrush current: 100 A for 264 VAC Output voltages:...
  • Page 24: Ambient Conditions

    VSB 40.1 Technical Data Ambient Conditions In operation Storage / Transport Maximum ambient temperature +5 °C... +45 °C -20 °C to +60 °C Exception: 230 V – UPS (see chapter 8.3) +0 °C ... +40 °C +0 °C ... +40 °C Max.
  • Page 25: Wear Parts

    Technical Data VSB 40.1 The devices of the VSB family are basically certified according to UL/CSA certification • UL508 (Industrial Control Equipment) and • C22.2 No. 142-M1987 (CSA) However, it is possible that there are combinations or extension stages with restricted or missing certification. Thus, verify the registration according to the UL marking on the device.
  • Page 26: Compatibility Check

    (e. g. lubricants in machine tools) which may interact with our controls and drives, it cannot be completely ruled out that any reactions with the materials used by Bosch Rexroth might occur. Therefore, test new lubricants, cleaning agents, etc. for compatibility with our housings / our housing materials before using the particular material concerned.
  • Page 27 Technical Data VSB 40.1 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 28: Dimensions And Installation Notes

    VSB 40.1 as variant LS (drive in connector direction) Each horizontal and vertical mounting direction is permissible. However, Bosch Rexroth recommends the mounting directions illustrated below. The space required for all the installation positions of connectors and cables as well as for the opening drive is to be considered at any time. A space of at least 50 mm is required on all sides in order to guarantee a sufficient cooling of the VSB 40.1...
  • Page 29: Mounting The Vsb 40.1, Variant Nn

    Dimensions and Installation Notes VSB 40.1 Mounting the VSB 40.1, Variant NN Horizontal Mounting with Connector Panel in Forward Direction Foto_Anschluesse_vorne.tif Connector panel in forward direction, Fig. 5-3: optional drive at the top Massbild_1_3d.FH9 Fig. 5-4: Dimensions for horizontal mounting with connector panel in forward direction DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 30: Vertical Mounting With Connector Panel In Forward Direction

    VSB 40.1 Dimensions and Installation Notes Vertical Mounting with Connector Panel in Forward Direction Foto_Anschluesse_vorne_vertikal.tif Fig. 5-5: Vertical Mounting with Connector Panel in Forward Direction (Distance mounting holes) (Distance mounting holes) XDPSLAVE 52.7 (Distance mounting - holes) (Distance mounting holes) 186.5 (Outer dimension) massbild_4_3d.FH11 Fig.
  • Page 31: Mounting With Connector Panel On The Top Side

    Dimensions and Installation Notes VSB 40.1 Mounting with Connector Panel on the Top Side Foto_Anschluesse_oben.tif Connector panel on the top side, Fig. 5-7: optional drive in forward direction Massbild_2_3d.FH9 Fig. 5-8: Dimensions when mounting the connector panel on the top side DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 32: Mounting The Vsb 40.1, Variant Ls

    VSB 40.1 Dimensions and Installation Notes Mounting the VSB 40.1, Variant LS Mounting with Connector Panel in Forward Direction Foto_Anschluesse_LS.jpg Fig. 5-9: Mounting with connector panel in forward direction Massbild_3_3d.FH9 Fig. 5-10: Dimensions when mounting the connector panel on the front DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 33: Installation Notes

    Dimensions and Installation Notes VSB 40.1 Installation Notes • Avoid installation locations exposed to direct sunlight, as additional heat development can occur. • When determining installation location and mounting position observe, that the optionally available drive can be opened unobstructed. •...
  • Page 34: Display And Operating Components

    Display To display and operate the VSB 40.1 we recommend the displays VDP 16 and VDP 40 especially designed by Bosch Rexroth for industrial applications. The displays are connected with the VSB 40.1 via the G4 display interface. Hence, you can install the display 30 meters away or more from the PC.
  • Page 35: Fig. 6-1: Intel Extreme Graphics

    Display and Operating Components VSB 40.1 If required, you can select, if the VDP connected with the G4 display Activation of the VDP or the external monitor interface, the external monitor operated at the VGA connection or both can be addressed: 1.
  • Page 36: Fig. 6-4: Confirm Desktop Change

    VSB 40.1 Display and Operating Components 4. If an external monitor is connected, you can select on the left side by clicking on the corresponding icons, if you want to address only the external monitor (select "Monitor"), only the screen of the connected VDPs (select "Notebook")
  • Page 37: Fig. 6-5: "Hot Keys

    Display and Operating Components VSB 40.1 RegisterTasten.bmp Fig. 6-5: “Hot Keys“ DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 38: Pc Box

    VSB 40.1 PC Box PC Box View on the Connector Panel XLAN XLAN XLPT XLPT XCOM XVGA XUSB XCOM XVGA XUSB VSB_Anschlüsse.FH11 Fig. 7-1: Position of connections of both the different designs DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 39: Interfaces

    PC Box VSB 40.1 Interfaces Note: Malfunctions caused insufficient shielding! Use only shielded cables and metallic/conductive connector or coupling covers with large-area screen contact. Overview Des. on the Connection type Connector type (integrated) Mating connector or cable housing (from outside) XCOM Serial interface: D-Sub male connector, 9-pin...
  • Page 40: Serial Interface Xcom

    VSB 40.1 PC Box Serial Interface XCOM XCOM - Serial interface A serial standard interface is provided at connection XCOM. D-Sub male connector, 9-pin Type: RS232 Cable length: 15 m max. Cable type: Shielded, cross section min. 0.14 mm² Transmission rate: Max.
  • Page 41: Parallel Interface Xlpt

    PC Box VSB 40.1 Parallel Interface XLPT XLPT – Parallel Interface for D-Sub female connector, 25-pin Printer, Scanner, etc. Type: SPP (ex works), EPP, ECP Cable length: 3 m max. Cable type: Shielded, cross section min. 0.14 mm² Interrupt (IRQ): I/O address: AUTO or 378H (recommended) XLPT...
  • Page 42: Xusb Interfaces

    VSB 40.1 PC Box XUSB Interfaces XUSB – serial interfaces for The devices feature two USB interfaces on the connector panel (XUSB). printer, scanner, CD-ROM drive These interfaces are compatible to USB 1.1 and USB 2.0. Note: The maximum power consumption of the connected devices must not exceed 500 mA.
  • Page 43: Ethernet Interface Xlan

    PC Box VSB 40.1 Ethernet Interface XLAN XLAN – Network Connection The industrial PC can be connected with an Ethernet network via an Ethernet interface XLAN. RJ45 female connector, 8-pin Type: Ethernet 10Base T / 100Base X Cable length: 100 m max. Cable type: Shielded, twisted pair Transmission rate:...
  • Page 44: Fig. 7-7: Vga Interface

    VSB 40.1 PC Box max. 1,5 m GREEN BLUE XVGA Display RED GND GREEN GND BLUE GND Digital GND Hsync Shield applied to the Vsync metal housing of the plug-in connector Vga_sst.cdr Fig. 7-7: VGA interface Setting incorrect resolutions and colors may destroy your monitor! ⇒...
  • Page 45: Keyboard Interface Xkb

    PC Box VSB 40.1 Keyboard Interface XKB XKB – PS/2 Mini DIN Keyboard / PS/2 Mini DIN female connector, 6- Mouse Interface Cable length: 1.5 m max. Cable type: Shielded, cross section min. 0.14 mm² max. 1.5 m Keyboard Data Keyboard Mouse Data Power, +5VDC...
  • Page 46: G4 Display Interface X71

    VSB 40.1 PC Box after completed startup, because the mouse initialization occurs during the booting process. Note: The connected mouse must be PS/2-compatible. Normally, the BIOS reserves IRQ 12 for the PS/2 mouse. If there are address conflicts, e. g., if IRQ 12 has already been used by another PC extension card, you should change the IRQ of this extension card to another IRQ, that is still not-assigned.
  • Page 47: Pc Power Supply

    7-10 PC Box VSB 40.1 PC Power Supply 24 VDC Power Supply This screw connection is used for device variants for 24 VDC. All internally required voltages are generated from the 24 VDC supply. Anschluss24V.jpg Fig. 7-10: Connection terminal for the 24 VDC supply Note: Only copper wire is to be used to connect these terminals.
  • Page 48: Fig. 7-12:Safety Transformer According To En 60742

    7-11 VSB 40.1 PC Box Danger without protective separation! ⇒ The 24 VDC input voltage must comply with the requirements of the "Protective separation". ⇒ Plug and unplug the connector only in no-voltage DANGER condition! 400V + 5% 400V 400V - 5% + 24V Sichertrafo.cdr Fig.
  • Page 49 7-12 PC Box VSB 40.1 (green/yellow) Power supply with safety transformer acc. to EN 60742 24 VDC Cross-sections depending on current consumption, min. of 4 mm . For higher current con- sumption use 2 x 4 mm . (blue) Length max. 4 m (green/yellow) Earth bar load...
  • Page 50: Fig. 7-16:Technical Data 115/230 Vac Connection

    7-13 VSB 40.1 PC Box This connection is used for device variants for 230/115 VAC. 230/115 VAC Power Supply All internally required voltages are generated by the 230/115 VAC power supply unit. The supply voltage must comply with overvoltage category II! Otherwise the integrated power supply unit might be destructed.
  • Page 51 7-14 PC Box VSB 40.1 Incoming mains (green/yellow) Min.16 To control cabinet housing (green/yellow) To machine (green/yellow) All housing components (PE bolt) (green/yellow) PE terminal bar for 0 V wiring (see fig. 2) PE star point (green/yellow) Fuses; motor protection key preferred Overvoltage (green/yellow) category III...
  • Page 52: Optional Serial Interfaces

    7-15 VSB 40.1 PC Box Optional Serial Interfaces According to the configuration, serial interfaces are available for the extension cards A5 and A6 on the slots. The interfaces have different pin assignments and signal assignments. Before using the interfaces, identify the type assignment or pin assignment, see the configuration sticker on the device (CFG-VSN01E1- xx-xx-xx-xx-xx-xx).
  • Page 53: Fig. 7-20:Pin Assignment Rs232, D-Sub Male Connector, 9-Pin

    7-16 PC Box VSB 40.1 CFG-VSN01E1-NN-NN-NN-NN-S3-S3 Serial Interface RS232 XCOM3 on Slot for Extension Card A5 Assignment DCD (Data Carrier Detect) RX (Receive Data) TX (Transmit Data) DTR (Data Terminal Ready) Signal Ground DSR (Data Set Ready) RTS (Request to Send) CTS (Clear to Send) RI (Ring Indicator) Fig.
  • Page 54: Fig. 7-23:Pin Assignment Rs232, D-Sub Male Connector, 9-Pin

    7-17 VSB 40.1 PC Box CFG-VSN01E1-NN-NN-NN-NN-NN-S2 Serial Interfaces RS232 and RS422 XCOM4 on Slot for Extension Card A6 Assignment DCD (Data Carrier Detect) RX (Receive Data) TX (Transmit Data) DTR (Data Terminal Ready) Signal Ground DSR (Data Set Ready) RTS (Request to Send) CTS (Clear to Send) RI (Ring Indicator) Fig.
  • Page 55: Fig. 7-26: Position Of The Connections And The Jumper On The Motherboard Variants

    7-18 PC Box VSB 40.1 Jumper Setting on Motherboard XCOM3 Jumper JPB2 Jumper JPB1 XCOM4 XCOM3 XCOM4 Jumper JPB1 Jumper JPB2 Motherbord 1070922809 Motherbord 1070923827 Lage_der_Anschlusse_auf_den_Motherbord-Varianten.FH11 Fig. 7-26: Position of the connections and the jumper on the motherboard variants Motherboard 1070922809 = Jumper JPB2 Motherboard 1070923827 = Jumper JPB1 XCOM3 9-10...
  • Page 56: Fig. 7-28:Pin Assignment Rs232, D-Sub Male Connector, 9-Pin

    7-19 VSB 40.1 PC Box CFG-VSN01E1-NN-NN-NN-NN-NN-S6 Serial Interfaces RS232 and RS422 (Rexroth Standard) XCOM4 on Slot for Extension Card A6 Assignment DCD (Data Carrier Detect) RX (Receive Data) TX (Transmit Data) DTR (Data Terminal Ready) Signal Ground DSR (Data Set Ready) RTS (Request to Send) CTS (Clear to Send) RI (Ring Indicator)
  • Page 57: Fig. 7-32:Jumper Positions For Termination Settings

    7-20 PC Box VSB 40.1 Note: There is no uniform and standard pin assignment for RS422. When connecting RS422 devices, the pinout in the documentation is always to be considered. Jumper Setting on Motherboard XCOM3 Jumper JPB2 Jumper JPB1 XCOM4 XCOM3 XCOM4 Jumper JPB1...
  • Page 58: Maintenance And Installation

    (see chapter "Wear parts" on page 4-4). This lithium battery may not be changed by the user. The battery may only be exchanged by the Bosch Rexroth Service (see chapter 14v "Service und Support") or by personnel especially trained and authorized by the Service.
  • Page 59: Connection Of The Uninterruptibe Power Supply

    "Accessories" on page 11-2). These USP devices bridge short voltage dips. Longer voltage dips cause and allow a normal shutdown of the operating system. Therefore, Bosch Rexroth recommends to use an UPS. The uninterruptible power system is connected to the voltage supply line.
  • Page 60: Hard Disk

    VSB 40.1 Maintenance and Installation Dimensions of the UPS USV_Montagemasse.eps Fig. 8-3: Installation dimensions UPS holder The depth of the UPS holder without mounting rail adapter is 117.5 mm and with mounting rail adapter 127 mm. Hard disk The installation frame of the hard disk can be accessed from the rear side of the VSB 40.1 or for variant LS from the bottom side of VSB 40.1.
  • Page 61: Fig. 8-4: Loosen The Fastening Screws At The Mounting Frame

    Maintenance and Installation VSB 40.1 Note: The hard disk to be inserted must already have an installed operating system, if no external boot medium is connected to the industrial PC. In any case, it is recommended to have a completely installed operating system on the hard disk, to shorten the installation time! The change of the hard disk for the two variants is not identic, as the hard disk is located at different positions.
  • Page 62: Fig. 8-5: Fastening Screws Of The Hard Disk Frame

    VSB 40.1 Maintenance and Installation 7. Loosen the fastening screws of the hard disk frame. The hard disk and (depending on the device design) the CD DVD drive are mounted on this plate: 83_Laufwerk2.JPG Fig. 8-5: Fastening screws of the hard disk frame 8.
  • Page 63: Fig. 8-7: Loosen The Fastening Screws At The Mounting Frame

    Maintenance and Installation VSB 40.1 16. After a regular booting of the PC, the user data as well as the operating system settings for the normal operating mode are to be restored. Changing the Hard Disk of the VSB 40.1, Variant LS 1.
  • Page 64: Fig. 8-10:Loosen The Cable From The Hard Disk

    VSB 40.1 Maintenance and Installation 7. Tip the VSB 40.1 to the left side. 83_LS_gekippt.JPG Fig. 8-9: Tip the VSB 40.1 to the left and remove it from the mounting plate 8. Now, you can loosen the cables (IDE and power supply) from the hard disk and put the VSB 40.1 on its left side.
  • Page 65: Fig. 8-11:Loosen The Fastening Screws Of The Hard Disk

    Maintenance and Installation VSB 40.1 9. Loosen the screws, with which the hard disk is mounted, with a Philips screwdriver by inserting it through the holes in the mounting frame. 83_LS_Schrauber.JPG Fig. 8-11: Loosen the fastening screws of the hard disk 10.
  • Page 66: Fig. 8-12: Location Of The Hard Disk With Damper

    VSB 40.1 Maintenance and Installation Exchanging Hard Disk with Damper In case of VSB devices containing hard disks with damper, the hard disk is located below the device, refer to Fig. 8-12. Position_der_schwingungsgedaempften_Festplatte.EPS Fig. 8-12: Location of the hard disk with damper In order to exchange the hard disk, remove the fastening screw of the hard disk installation frame on the bottom side of the VSB 40.1 (refer to Fig.
  • Page 67: Extension Cards

    8-10 Maintenance and Installation VSB 40.1 Extension Cards To plug extension cards slots for the PCI bus are available. Risk of damage to the operator terminal or the extension cards by electrostatic discharges! ⇒ Comply with all ESD-protection measures during working with modules and components! Avoid CAUTION! electrostatic discharges!
  • Page 68: Fig. 8-15:Lift The Cover With Fan

    8-11 VSB 40.1 Maintenance and Installation 5. Lift up the cover with the fan. 84_Deckeloffen.JPG Fig. 8-15: Lift the cover with fan 6. Loosen the fastening screw of the corresponding extension card and remove it: 84_Slotblech2.JPG Fig. 8-16: Remove extension card 7.
  • Page 69: Bios Settings

    8-12 Maintenance and Installation VSB 40.1 8. Fasten the plug-in assembly with the screw, with which the extension card was fixed. 84_neueKarte2.JPG Fig. 8-17: Fix the new PCI card with the screw 9. Close the top cover and fasten it with the two screws. If the card is equipped with a Plug and Play (PnP) function, it is automatically recognized by the operating system and integrated in the system, provided that no hardware conflicts (IRQ etc.) with other...
  • Page 70: Software

    VSB 40.1 Software Software UPS Software The software required for the optionally available UPS (see chapter 8.3 "Connection of the Uninterruptible Power Supply" on page 8-2 and section chapter "Uninterruptible Power Supply" on page 11-2) is stored on the hard disk of the VSB 40.1. Before being able to use this software, you have to install it.
  • Page 71: Fig. 9-2: Dialog Window To Set The Touch Screen

    Software VSB 40.1 The following dialog window appears for the different settings: UPDD_settings.bmp Fig. 9-2: Dialog window to set the touch screen For more detailled information, please select the Help button on the respective tab. Via "Start -> Programs -> UPDD" you reach further useful programs, if required.
  • Page 72: Disposal And Environmental Protection

    Furthermore, the products returned for disposal must not contain any undue foreign matter or foreign component. Please send the products free domicile to the following address: Bosch Rexroth AG Electric Drives and Controls Bürgermeister-Dr.-Nebel-Straße 2 97816 Lohr am Main, Germany Packaging Materials The packaging materials consist of cardboard, wood and polystyrene.
  • Page 73: Recycling

    10-2 Disposal and Environmental Protection VSB 40.1 Recycling Due to their high content of metal most of the product components can be recycled. In order to recycle the metal in the best possible way, the products must be disassembled into individual modules. Metals contained in electric and electronic modules can also be recycled by means of special separation processes.
  • Page 74: Ordering Information

    11-1 VSB 40.1 Ordering Information Ordering Information 11.1 Type Code Designation VSB40.1 According to the following type code designation, the IPC VSB 40.1 is available in different variants. Abbrev. column 1 2 3 4 6 7 8 9 1 2 3 4 6 7 8 9 1 2 3 4 6 7 8 9...
  • Page 75: 11.2 Accessories

    11-2 Ordering Information VSB 40.1 11.2 Accessories Network Connection Ordering designation Part number Description B-AC STECKER NETZ 230V 1070 912881 Mains connector 230 V, male inlet connector for non- heating apparatus, angular, for self-mounting BKS-U-N-NTZKAB-IPCRHO-002,5-P 1070 048937 Mains cable 230 V with female inlet connector for non- heating apparatus, angular, cable length 2.5 m Fig.
  • Page 76: List Of Figures

    12-1 VSB 40.1 List of Figures List of Figures Fig. 1-1: VSB 40.1 1-1 Fig. 3-1: Hazard classification (according to ANSI Z535) 3-1 Fig. 4-1: Technical data: PC box 4-1 Fig. 4-2: Technical data of the power supply unit 115 V / 230 V 4-2 Fig.
  • Page 77 12-2 List of Figures VSB 40.1 Fig. 7-15:Pin assignment of the 230/115 VAC connection X20 7-13 Fig. 7-16:Technical data 115/230 VAC connection 7-13 Fig. 7-17:Voltage connection 230 VAC via isolating transformer 7-14 Fig. 7-18:Pin assignment RS232, D-sub male connector, 9-pin 7-15 Fig.
  • Page 78 12-3 VSB 40.1 List of Figures Fig. 11-2:Connectors and cables for VSB 40.1 11-2 Fig. 11-3:Connecting cables to the VDP 16.1, VDP 40.1 and VDP 60.1 11-2 Fig. 11-4:Uninterruptible power supply 11-2 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 79 12-4 List of Figures VSB 40.1 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 80: Index

    13-1 VSB 40.1 Index Index Activate monitor 6-2 Activate VDP 6-2 Air pressure 4-3 Ambient conditions 4-3 Appropriate use Area of application 2-2 Introduction 2-1 Areas and Use of Application 2-2 BIOS settings 8-12 Buffer battery 8-1 CE marking 4-3 CMOS Battery 8-1 Commissioning 1-2 Compatibility check 4-5...
  • Page 81 13-2 Index VSB 40.1 Inappropriate use 2-2 Consequences, Discharge of liability 2-1 Insert an extension card 8-10 Installation notes 5-1, 5-6 Interfaces 7-2 Ethernet 7-6 Keyboard interface 7-8 PS/2 keyboard 7-8 PS/2 mouse 7-8 Serial interface XCOM 7-3 XLPT 7-4 XUSB 7-5 XVGA 7-6 KB –...
  • Page 82 13-3 VSB 40.1 Index Recycling 10-2 Relative humidity 4-3 Safety Instructions for Electric Drives and Controls 3-1 Safety transformer according to EN 60742 7-11 Serial interface XCOM 7-3 System presentation Brief description 1-1 System representation 1-1 Commissioning 1-2 Operating system 1-1 Technical data 115/230 VAC connection 7-13 24 VDC connection 7-10...
  • Page 83 13-4 Index VSB 40.1 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 84: Service And Support

    14-1 VSB 40.1 Service and Support Service and Support 14.1 Helpdesk Our service helpdesk at our headquarters in Lohr, Germany, will assist you with all kinds of inquiries. Contact us: • By phone through the Service Call Entry Center Monday to Friday: 7:00 am – 6:00 pm CET +49 (0) 9352 40 50 60 •...
  • Page 85 14-2 Service and Support VSB 40.1 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...
  • Page 87 Bosch Rexroth AG Electric Drives and Controls P.O. Box 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Phone +49 (0)93 52-40-50 60 +49 (0)93 52-40-49 41 service.svc@boschrexroth.de www.boschrexroth.com Printed in Germany R911310079 DOK-SUPPL*-VSB*40.1***-PR02-EN-P...

This manual is also suitable for:

Vsb40.1g4e-512nn-c1c-ae-ls-fw

Table of Contents