Battery Connection X19 - Bosch Rexroth lndraControl VPB 40.1 Project Planning Manual

Control cabinet pc
Table of Contents

Advertisement

44/81
Bosch Rexroth AG
Connections
Incom ing m ains
Don't use the neutral
conductor "N"
without permission
of the operator!
E.g., drives
7.2.12

Battery Connection X19

X19 Battery Connection
2
(green/yellow)
Min.16
mm
2
mm
16
(green/yellow)
2
(green/yellow)
6
mm
2
mm
(green/yellow)
10
PE star poin
t
2
16
mm
(green/yellow)
Fuses; motor protection key preferred
400V
Transformer as per
EN 60742
230V
2
(green/yellow)
4
mm
PE
N1
230 V supply
operator terminals
service plug receptacles
Fig.7-26:
AC 230 V voltage connection via isolating transformer
DANGER
Power supply units, whose net connection is designed for overvoltage category
II, are to be connected to a net voltage with overvoltage category II, see
7-26 "AC 230 V voltage connection via isolating transformer" on page
Connection terminal for an external battery for the integrated UPS:
2-pin
Cable length
Cable type
Fig.7-27:
Battery connection - X19
DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
To control cabinet housing
To machine
All housing components (PE bolt)
PE terminal bar for 0 V wiring
(see fig. 2)
2
4
mm
(green/yellow)
U2
PE
2
(green/yellow)
4
mm
: Terminals in isolated configuration
High electrical voltage! Danger to life and risk
of injury caused by electric shock or bodily
harm caused by net voltage on the protective
extra-low voltage (e.g. +24V)! Connection of
power supply units, which cause protective ex‐
tra-low voltage, to net voltages, for which they
are not designed.
3.0 m max.
Unshielded, cross-section min. 1.5 mm
Overvoltage
category III
Overvoltage
category II
fig.
44.
2

Advertisement