Grizzly G0771Z Manual page 73

Table of Contents

Advertisement

Table/Dado Insert
Adjustment
The table/dado insert must sit perfectly flush with
the table to provide a smooth, continuous surface
for the workpiece to slide over. The insert is held
in place by a magnet and sits on top of five adjust-
ment screws (see Figure 127).
The insert should be checked and adjusted any
time it is removed and replaced, after prolonged
use, or any time you notice the workpiece or fence
does not slide smoothly over the insert.
Figure 127. Location of table/dado insert holes
with adjustment screws.
-70-
Tools Needed
Phillips Head Screwdriver #2 ............................ 1
Straightedge ...................................................... 1
To check and adjust insert:
1.
DISCONNECT MACHINE FROM POWER!
2.
Place straight edge across insert and check
to make sure insert is flush with table at front
and back of throat.
— If insert is flush with table, no adjustments
are necessary.
— If insert is not flush with table, proceed to
Step 3.
3.
Insert screwdriver through holes shown in
Figure 127 and either loosen screws to raise
insert, or tighten screws to lower it. Repeat
Steps 2–3 until insert is perfectly flush with
surface of table.