Nose adapter
1
► 1. Nose adapter
The nose adapter prevents the surface of workpiece
from being scratched or damaged. Place the nose
adapter correctly.
Store the nose adapter in place when not in use. The
place for storage is on the bottom sides of the tool.
► 1. Nose adapter
Short nail adapter
► 1. Short nail adapter
1
1
► 1. Short nail adapter 2. Bolt
Attach the short nail adapter to prevent the short nails
from being jammed when you use nails shorter than 25
mm (1 ").
Insert the short nail adapter into the slit in the rear of the
magazine. Then fix the adapter by tightening the bolt.

OPERATION

WARNING:
Do not touch around the exhaust vent. The
surface will be very hot during or after an oper-
ation. Touching around the exhaust vent may
cause burns or injuries.
CAUTION:
Make sure all safety systems are in working
order before operation.
Checking proper action before
operation
Before operation, always check following points.
Make sure that the tool does not operate only by
installing the battery cartridge and fuel cell.
Make sure that the tool does not operate only by
pulling the trigger.
Make sure that the tool does not operate only by
placing the contact element against the workpiece
without pulling the trigger.
Make sure that the tool does not operate when
pulling the trigger first and then placing the contact
element against the workpiece.