12.

POSITION OF TENSION RELEASE SOLENOID

STANDARD
When the tension release solenoid is off, the gap between tension release plates A and B should be 0 - 0.5 mm,
and the gap between tension release plate A and the tension release solenoid shaft should be 0 mm.
ADJUSTMENT
1.
Lower the presser foot lever.
2.
Loosen the two screws of the solenoid holder.
3.
Shift the solenoid holder right or left to adjust the gap between tension release plate A and B.
4.
Tighten the two screws of the solenoid holder.