Makita 191D73-9 Instruction Manual page 6

Cyclone attachment
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
NOTE
• Check that the cyclone attachment, cleaner, and straight pipe are all firmly
connected before restarting operation.
• If the suction force does not recover even after disposing of the dust and
cleaning the mesh filter, check whether dust has accumulated in the dust bag
or paper dust pack of the cleaner or clogging has occurred.
Cleaning
• When the dust case becomes dirty or the mesh filter is clogged, remove and wash
them with water.
(Refer to "Disposing of dust" for the removal procedure.)
• Dry the parts thoroughly before reinstallation and use.
Fig. 4 : 1. Dust case 2. Mesh filter
When the mesh filter gets dirty badly, clean it in the following procedures.
1. Turn the mesh filter counterclockwise and remove it while the hooks are unlocked.
Fig. 5 : 1. Mesh filter 2. Hook
2. Remove the dust on the mesh filter and then wash it with water. After that, dry it
thoroughly.
3. Insert the mesh filter into the base while the hooks are aligned with the port. Turn the
mesh filter clockwise until the hooks are locked with a click. Make sure that the mesh
filter is installed securely.
Fig. 6 : 1. Mesh filter 2. Hook 3. Port