Acs 160 Complete Parameter List - ABB ACS 160 User Manual

Driveit low voltage ac drives
Table of Contents

Advertisement

ACS 160 Complete Parameter List

Initially, only the so called basic parameters (shaded grey in the table below) are visible. Use the
appropriate menu function of the control panel to make the full parameter set visible. Refer to Menu
Functions.
Note! InterBus-S (CFB-IBS) and CANopen (CFB-CAN) Users: The Parameter Index equal Drive
Parameter No. + 12288 converted to hexadecimal. Example: the index for drive parameter 1309 is
1309 +12288 = 13597 = 351Dh.
S = Parameters can be modified only when the drive is stopped.
M = Default value depends on the selected macro.
Code Name
Group 99
START-UP DATA
9902
APPLIC MACRO
9905
MOTOR NOM VOLT
9906
MOTOR NOM CURR
9907
MOTOR NOM FREQ
9908
MOTOR NOM SPEED
9909
MOTOR NOM POWER
9910
MOTOR COS PHI
Group 01
OPERATING DATA
0102
SPEED
0103
OUTPUT FREQ
0104
CURRENT
0105
TORQUE
0106
POWER
0107
DC BUS VOLTAGE
0109
OUTPUT VOLTAGE
0110
ACS TEMP
0111
1
EXTERNAL REF
0112
2
EXTERNAL REF
0113
CTRL LOCATION
0114
(
)
RUN TIME
R
0115 kWh
(
COUNTER
R
0116
APPL BLK OUTPUT
0117
1-
4
DI
DI
STATUS
0118
1
AI
0119
2
AI
0121
5 &
DI
RELAYS
ACS 160 User's Manual
Range
0 - 7,14
380, 400, 415,
440, 460, 480,
500 V
0.5*I
- 1.5*I
N
N
0 - 250 Hz
0 - 3600 rpm
0.1 - 100 kW
0.50 - 0.99
0 - 9999 rpm
0 - 250 Hz
-
-
-
0 - 999.9 V
0 - 500 V
0 - 150 ° C
0 - 250 Hz
0 - 100 %
0 - 2
0 - 9999 h
)
0 - 9999 kWh
0 - 100 %
0000 - 1111
(0 - 15 decimal)
0 - 100 %
0 - 100 %
0000 - 0111
(0 - 7 decimal)
Default /
Resolution
US Default
1
0 (
FACTORY
-
400 V / 460 V
0.1 A
1.0*I
N
1 Hz
50 Hz / 60 Hz
1 rpm
1440 rpm /
1750 rpm
0.1 kW
*
0.01
0.83 / 0.83
1 rpm
-
0.1 Hz
-
0.1 A
-
0.1 %
0.1 kW
-
0.1 V
-
0.1 V
-
0.1 ° C
-
0.1 Hz
-
0.1 %
-
1
-
1 h
-
1 kWh
-
0.1 %
-
1
-
0.1 %
-
0.1 %
-
1
-
Profibus
par. num User
)
1927
1930
1931
1932
1933
1934
1935
2
3
4
5
6
7
9
10
11
12
13
14
15
16
17
18
19
21
S
M
ü
ü
ü
ü
ü
ü
ü
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents