Application Macros

Application Macros are preprogrammed parameter sets. They minimise the number of different
parameters to be set during start-up. The Factory Macro is the factory-set default macro.
Note! The Factory Macro is intended for applications where there is NO control panel available. If
using the Factory Macro with control panel note that the parameters whose value depend on
the digital input DI4 cannot be modified from the panel.
Note! Selecting an application macro with parameter 9902
parameters to their default values, except the group 99 Start-up Data parameters, the parameter
lock 1602, and groups 51 - 52 serial communication parameters.
Default values of certain parameters depend on the selected macro. These are listed with the
description of each macro. Default values for other parameters are given in ACS 160 Complete
Parameter List.
Connection Examples
In the following connection examples please note:
All the digital inputs are connected using negative (NPN) logic.
List of available macros:
1. Application Macro Factory (0)
2. Application Macro Factory (1)
3. Application Macro ABB Standard
4. Application Macro 3-wire
5. Application Macro Alternate
6. Application Macro Motor Potentiometer
7. Application Macro Hand - Auto
8. Application Macro PID Control
9. Application Macro Premagnetise
10. Application Macro Positioning
ACS 160 User's Manual
will set all other
APPLIC MACRO
33