Troubleshooting Troubleshooting Chart 1-10, SB9600 BUS RX

Troubleshooting Chart 1-10, SB9600 BUS RX

Perform the following while sending data.
68P81083C20-D
START
i.e. Control Head button press,
Channel Change, Radio OFF/ON.
Voltages on
No
SB9600 Voltage
Table correct?
Yes
Data
No
J0403-6,
J0403-18?
Yes
Data
No
U0401-2 pin 6,
U0401-2 pin 5?
Yes
Data
No
U0105-13?
Yes
Data
No
U0105-14?
Yes
Data
No
U0103-63?
Yes
Check
U0103
Failure
No
persists?
Yes
GOTO SB9600
Tx Chart 1-11
Note: For SB 9600 operation the SCI RX,
SCI TX, and Busy paths must all function.Ê
Correct as required.
Suggestion: Check for
shorted zener diodes.
Check VR0420,
VR0419
Check R0410,
R0411, C0437
Check
R0130, U0401
U0105
Yes
OK?
No
Repair or replace
U0105
Check
R0129
Problem
Fixed
Check
Q0103, VR0428