Download Print this page

Honeywell COMBISAFE ESCALIB Manual page 13

Site spiral stair tower with side exit

Advertisement

Example:
An 8-module Escalib located in Paris is subject to a peak wind pressure q p of 54 daN/m²,
corresponding to a wind speed of 107 km/h.
In configuration I, the Escalib is anchored every 3 modules.
Each anchors must withstand the following stresses:
- shearing : V = 300 daN,
- pullout : T = 200 daN.
WARNING:
The holes drilled in the foot plates are to be used to nail through to wooden blocks when it is neces-
sary to spread the load on the ground. They must not be used to anchor the Escalib.
Anchorage :
ESCALIB BEAM COUPLER
Description
Escalib beam coupler
Slip force: 515 daN SLS.
This beam coupler can be positioned anywhere on the
module uprights.
13
WWW.COMBISAFE.COM
Code
Weight (kg)
CT50001
2.0
Anchor arm
Dimensions
0.500 m
(wall plugs not included)
Code
Weight (kg)
CT50004 2.7