Download Print this page

ABB ACH580-01 Installation, Operation And Maintenance Manual page 61

Hide thumbs Also See for ACH580-01:

Advertisement

ACH580 Installation, Operation and Maintenance Manual
Code
(hex)
(none)
1
A4A1
IGBT overtemperature
A4A9
Cooling
A4B0
Excess temperature
A4B1
Excess temperature
difference
A4F6
IGBT temperature
A581
Fan
Warning / Aux. code
Temperature above
warning limit
Thermistor broken
Estimated drive IGBT
temperature is
excessive.
Drive module
temperature is
excessive.
Power unit module
temperature is
excessive.
High temperature
difference between the
IGBTs of different
phases.
Drive IGBT
temperature is
excessive.
Cooling fan feedback
missing.
Cause
What to do
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Contact an ABB service
representative for control board
replacement.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive
power.
Check ambient temperature. If it
exceeds 40 °C/104 °F (IP21 frames
R4
R9) or if it exceeds 50 °C /122 °F
...
(IP21 frames R1
load current does not exceed derated
load capacity of drive. For all P55
frames, check the derating
temperatures. See chapter Technical
data, section Derating in the
Hardware manual of the drive.
Check drive module cooling air flow
and fan operation.
Check inside of cabinet and heatsink
of drive module for dust pick-up.
Clean whenever necessary.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive
power.
Check the motor cabling.
Check cooling of drive module(s).
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive
power.
Check the auxiliary code to identify
the fan. Code 0 denotes main fan 1.
Other codes (format XYZ): "X"
specifies state code (1: ID run, 2:
normal). "Y" = 0, "Z" specifies the
index of the fan (1: Main fan 1, 2:
Main fan 2, 3: Main fan 3).
Check fan operation and connection.
Replace fan if faulty.
ACH580-01 Installation
61
R9), ensure that
...

Advertisement

loading