6. Navigate to View/Edit > Configure by Group > Radio Configuration, and set the following
parameters.
Item No.
3071
3016
3021
3022
3064
3023
7. Cloud Link must be externally powered and modem session timeout must be
configured to 180 seconds if MiWireless mode is enabled.
Item No.
3142
3028
8. Disconnect MasterLink.
9. Power cycle the CNI4.
Step 7: Restore the original serial cable connection
1. Disconnect the USB to serial cable (40-6147-kit).
2. Restore the original serial interface between the Pulse Accumulator and the Cloud Link
4G Modem.
Step 8: Close and lock the door
CNI4 Quick Start Guide
Description
Verizon enable
Fetch
Radio
Parameters
ModemIPType
Packet service
Connection
command
Manual
APN
Enable
APN Name
Description
MiWireless Enable
Modem session timeout
Verizon
1 = Enable
1 = Set
2 = IPv4v6
ATD*99***3#
1 = Enable
Provided
by
Verizon
Recommended Value
1 = Enable
180 seconds
Non-Verizon
0 = Disable
1 = Set
0 = IPv4
ATD*99#
1 = Enable
Example
for
AT&T: 12221.mcs
8

Advertisement

loading