Communication log data read request: logrd( )
[Linking procedure]
Main
Struct logr_p {
long node ;
unsigned short *Erradr ;
unsigned char *logadr ;
} ;
long (*Logrd)( ) ;
long rtn ;
struct logr_p *padr ;
Logrd = (long(*)( ))0xD600E0 ;/* S10V */
rtn = (*Logrd)(padr) ;
[Parameters for mathematical/logical function]
C language
+0x0000
Message transmission service number (10)
+0x0004
Remote node number (1 to 254)
+0x0008
Error code storage address
+0x000C
Log data storage address
Struct logr_p {
long node ;
unsigned short *Erradr ;
unsigned char *logadr ;
} ;
long (*Logrd)( );
long rtn ;
struct logr_p *padr ;
Logrd = (long(*)( ))0xDE00E0 ;/* S10V */
rtn = (*Logrd)(padr) ;