Safety
Safety
WARNING
HIGH VOLTAGE!
Adjustable frequency drives contain high voltage when
connected to AC line power. Installation, startup, and
maintenance should be performed by qualified personnel
only. Failure to perform installation, startup, and
maintenance by qualified personnel could result in death
or serious injury.
High Voltage
Adjustable frequency drives are connected to hazardous
AC line voltage. Extreme care should be taken to protect
against shock. Only trained personnel familiar with
electronic equipment should install, start, or maintain this
equipment.
WARNING
UNINTENDED START!
When the adjustable frequency drive is connected to AC
line power, the motor may start at any time. The
adjustable frequency drive, motor, and any driven
equipment must be in operational readiness. Failure to be
in operational readiness when the adjustable frequency
drive is connected to AC line power could result in death,
serious injury, equipment, or property damage.
Unintended Start
When the adjustable frequency drive is connected to AC
line power, the motor may be started with an external
switch, a serial bus command, an input reference signal, or
a cleared fault condition. Use appropriate caution to guard
against an unintended start.
WARNING
DISCHARGE TIME!
Adjustable frequency drives contain DC link capacitors that
can remain charged even when the adjustable frequency
drive is not powered. To avoid electrical hazards,
disconnect AC line power, any permanent magnet type
motors, and any remote DC link power supplies, including
battery backups, UPS and DC link connections to other
adjustable frequency drives. Wait for the capacitors to fully
discharge before performing any service or repair work.
The wait time required is listed in the Discharge Time table.
Failure to wait for the specified period of time after power
has been removed to do service or repair could result in
death or serious injury.
TM
AF-650 GP
Design and Installation Guide
Voltage
200–240 V
380–480 V
525–600 V
525–690 V
Discharge Time
Symbols
The following symbols are used in this manual.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may
also be used to alert against unsafe practices.
CAUTION
Indicates a situation that may result in equipment or
property damage-only accidents.
NOTE!
Indicates highlighted information that should be observed
in order to avoid mistakes or operate equipment at less
than optimal performance.
Approvals
Table 1.2
DET-767A
Power Size
0.25–3.7 kW 1/3–5 HP
5.5–37 kW 7.5–50 HP
0.37–7.5 kW 1/2–10 HP
11–75 kW 15–100 HP
90–200 kW 125–300 HP
250–800 kW 350–1200 HP
0.37–7.5 kW 1/2–10 HP
11–75 kW 15–100 HP
11–75 kW 15–100 HP
90–315 kW 125–400 HP
355–1200 kW 500–1350 HP
Minimum
Waiting Time
4 minutes
15 minutes
4 minutes
15 minutes
20 minutes
40 minutes
4 minutes
15 minutes
15 minutes
20 minutes
30 minutes