Page 1
Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.com PURUS CP Operation / Maintenance Manual SERIAL NUMBER (located on top of product): 02/10/2016– MPCP-A...
INTRODUCTION Purus CP – A Revolutionary PFA High-Purity, Low-Pulsation Pump! TREBOR’S Purus CP diaphragm pump offers a unique solution to critical applications requiring stable flow and low pulsation. With a revolutionary injection molded PFA design, Trebor has created an ultrapure pump utilizing proven components with minimal parts. This manufacturing approach has created a reliable, leak proof, disposable pump that costs less than most competitors’...
INTENDED USE AND AUDIENCE The Purus CP pump is designed to safely pump liquids up to 120°C. This manual only covers the Trebor Purus CP pump and pump accessories provided by Trebor. The Purus CP pump is not to be used for proposes other than that which it is designed for.
SAFTEY SAFETY PRECAUTIONS This section provides important information for safe operation of the Purus CP pump. The equipment described in this manual can be used to pump hazardous chemicals that can be dangerous. Local policies and procedures for safely operating any Trebor Purus CP pump(s) supersede the safety considerations listed below.
INSTALLATION Ensure all system interlock and safety devices are functional prior to operation (refer to Section 2, Safety Requirements). Before starting the system, it is important to read and understand Section 4, Operation. Only trained, qualified, authorized personnel should operate this pump. Figure 3-1: Dimensions (in / [cm]) PAGE 6 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL...
Refer to Troubleshooting Section 7 if pump fails to start or contact Trebor for further assistance. ATTENTION: The pump should be operated with clean, dry air or nitrogen. Particulate, water and oils in the air supply can damage or contaminate the pump air chamber. NOTE: The Purus CP can be operated dry for extended periods up to 24 continuous hours.
Page 10
Figure 4-2: Pressure and Flow Capacity Chart The preceding chart defines a region of operation over which the Purus CP pump may be operated with a PC15 pump controller with a discharge flow variance of less than +/-1.5% of nominal value. Figure 4-3: Purus CP Recommended Temperature Curve PAGE 10 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL...
INSPECTION AND MAINTENANCE MAINTENANCE The Purus CP has no serviceable parts. Pumps removed from service, decommissioned, or dismantled should be decontaminated and disposed of per company policy. MATERIALS LIST 5.2.a Wetted Materials PFA and PTFE 5.2.b Non-wetted Materials PVDF and PP NOTE: PURUS CP has no serviceable parts.
PC15 (OPTIONAL) INSTALLATION PC15 OVERVIEW The PC15 Pump Controller is designed specifically to operate Trebor’s Purus CP pump. Cross-phase timing results in overlapping pump strokes which produces a near pulse-less pump output. PC15 controllers can be configured depending on flow requirements (See QIG manual) PC15 INSTALLATION The PC15 pump controller can be installed in any orientation.
PC15 UTILITIES / HOOK-UP Utility Pump 3/8” Diameter supply tube. Air Inlet: Air Supply: 50-80 PSIG (.55±.03 MPa Max), clean dry air or inert Power 24VDC - 500mA Controller Weight: 4.4 lbs (2.0 Kg) ATTENTION: Air supplied to the PC15 pump controller must be regulated to 50 - 80 PSIG to operate the vacuum venturi.
PC15 CONTROLLER OPERATION Ensure that all system interlock and safety devices are functional prior to operation. Before starting the system, it is important to read and understand the PC15PC manual. Only trained, qualified, authorized personnel should operate this pump controller. The controller is operated by using the buttons located on the PLR, see Table 6-1.
WARRANTY AND EXCLUSIONS See the Trebor Standard Limited Warranty at www.idex-hs.com/support/trebor/downloads/TreborStandardLimitedWarranty_02-07.pdf PAGE 16 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL...