Sizing Of Enclosure And Control Cabinet; Mounting Hcs01 Devices In The Control Cabinet - Bosch Rexroth IndraDrive HCS01 Series Instruction Manual

Drive controllers power sections
Hide thumbs Also See for Rexroth IndraDrive HCS01 Series:
Table of Contents

Advertisement

34/65
Bosch Rexroth AG | Electric Drives
Instructions for Use
5.3.2

Sizing of Enclosure and Control Cabinet

Mounting HCS01 Devices in the Control Cabinet

Notes on Mounting
Required Steps to Follow
and Controls
1
Control cabinet wall
2
Left-hand mounting
3
Back-side mounting (standard mounting)
4
Right-hand mounting
Fig.5-18:
Options for Mounting HCS01 Devices in the Control Cabinet
The back-side mounting (back of device directly mounted to control cab‐
inet wall) is the standard and should be used, if possible.
The left-hand or right-hand mounting (left or right side of device directly
mounted to control cabinet wall) can be used, if the mounting clearance
between control cabinet wall and control cabinet front is not sufficient for
back-side mounting.
CAUTION! Risk of damage by high temperatures! At the back of the
HCS01 devices, there are braking resistors which can become very hot
during operation. When arranging the devices in the control cabinet, make
sure there aren't any heat-sensitive materials close to the braking resis‐
tors.
In the case of left-hand or right-hand mounting, you must not pile the de‐
vices. Each device must have immediate contact to the control cabinet
wall.
Observe the minimum distances to be complied with for mounting (see
technical data or dimensional drawings).
The specified horizontal minimum distance refers to the distance to neigh‐
boring devices and not to the distance to the control cabinet wall.
Tightening torque of the mounting screws: 6 Nm
On the sides of the devices, there are adhesive labels with notes on safe‐
ty. The supplied accessory HAS09 additionally contains these adhesive
labels. If the adhesive labels at the devices are no longer visible after
mounting, place the adhesive labels from the accessory HAS09 clearly
visibly at the device or in the immediate vicinity of the device.
HCS01 drive controllers were designed for control cabinet mounting. They are
mounted with two screws (M6×20; contained in the supplied accesso‐
ry HAS09).
Rexroth IndraDrive | Instruction Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents