Installing The Collector Clamp On The Left; Hydraulic Connection - Bosch TSS Series Installation And Maintenance Instructions Manual

Thermosiphon system, on-roof installation
Table of Contents

Advertisement

CAUTION:
Risk of injury and leaks from escaping solar heat transfer medium as
a result of unsecured solar hoses.
▶ Secure every solar hose to the collector connection using a hose clip.
▶ Tighten the circlip when the hose clip is located directly in front of the
bead.
Fig. 47 Fully assembled connection hose
8.6

Installing the collector clamp on the left

▶ Push the collector clamp into the profile rail and let it click into the
slot.
▶ Tighten the screw of the collector clamp.
Fig. 48 Installing the collector clamp on the left
TSS – 6720887693 (2018/10)
9

Hydraulic connection

NOTICE:
Leaks from using non-approved thread sealing compound!
If pipe threads are caulked with hemp:
▶ Use temperature-resistant thread sealing compound
(e.g. Neo Fermit).
NOTICE:
No solar-heated water from incorrectly installed flow and return
pipes!
To enable the heat transfer medium to flow from the collector into the
storage tank through different densities and for optimal venting:
0010014499-01
▶ Always install flow and return pipes with a rising gradient to the
storage tank.
▶ Bend the flow and return pipes with a sufficiently large radius.
0010014500-01
Fig. 49 Do not install a pipe trough (here: flow pipe)
Fig. 50 Ensure that the solar hose is not kinked
Hydraulic connection
0010015761-02
0010015400-01
19