    Underwriters Laboratories Information ..................7 National Electrical Code (NEC) ....................7 LOCATION OF SOLAR MODULES ....................7 Orientation, Tilt Angle, Shading, & Performance ................ 7 BOSCH SOLAR ENERGY MODULE CHARACTERISTICS ............8 Electrical Characteristics ......................8 Thermal Characteristics ....................... 8 Bypass diodes ..........................9 Mechanical Specifications ......................
  • Page 3 Unpacking Instructions ....................... 17 Safety Considerations ........................ 17 PRODUCT SUPPORT ........................18 CARE AND MAINTENANCE ..................... 18 Module Cleaning ........................18 Inspection and Repair ........................ 18 END OF LIFE ..........................19 Copyright Bosch Solar Energy Corp., version 1.0 Page 3 of 19...
  • Page 4: Introduction

    Bosch Solar E n e r g y assumes no responsibility for infringement of patents or other rights of third parties which may result from use of the module. No license is granted by implication or otherwise under any patent or patent rights.
  • Page 5: Installation Precautions

    Take special note of occupational safety and accident prevention regulations applicable to the work in question. Bosch Solar modules can be combined with other components to form a photovoltaic system. In this case you must also follow the installation and operation instructions issued for these additional components.
  • Page 6: Electrical And Optical Safety

    D. Fire Safety The Bosch Solar Energy c-Si M60 NA 30119 modules have been certified by Underwriters Laboratories to comply with UL1703 Class C fire rating. To satisfy the conditions of this rating when installing on a building, you must mount the modules using standoff or rack methods over a fire resistant roof covering rated for the application.
  • Page 7: Module Performance And Safety Standards

    Standard Test Conditions. B. Underwriters Laboratories Information These Bosch Solar Energy modules are listed to UL 1703, the Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. This Standard covers solar PV modules intended for...
  • Page 8: Bosch Solar Energy Module Characteristics

    If there are questions regarding the optimum configuration in which to arrange, mount or wire the modules, obtain assistance from your Bosch Solar Energy dealer or distributor or retain the services of an engineer familiar with the proper design of PV systems.
  • Page 9: Bypass Diodes

    There are no user serviceable parts inside. Opening the junction box may expose the individual to an electrical shock hazard and will void the warranty. D. Mechanical Specifications The Bosch Solar Energy module dimensions are summarized in the table below. Mechanical Characteristic c-Si M60 NA 30119 Model Designator (Part No.
  • Page 10: Mechnical Installation

    A. Module Orientation and Handling Safety Bosch Solar Energy PV modules can be arranged in either landscape or portrait position on flat or sloped roofs or surfaces and at flat or tilted angles. Always use caution when mounting a module on tilted angles or sloped roofs so the module does not slide out of position while attaching it to the module mounting system.
  • Page 11: Wind And Snow Loads

    PV systems. It is important to reference the most current revision of ASCE 7 for determining the proper wind and snow load calculations for the project site. Bosch Solar Energy modules have been evaluated by UL for a maximum positive or negative design loading of 50 lbs/ft (2,400 Pa).
  • Page 12: Electrical Interconnections

    +/- 1” (25 mm) of the centerline of the factory mounting hole. CAUTION: Contact Bosch Solar Energy if only the short frame edges are to be used for anchoring the module. This type of mounting method typically requires additional analysis by Bosch Solar Energy. Failure to do so may invalidate the warranty.
  • Page 13 For wiring that is exposed to weather, select conductor cable that is sunlight (UV) resistance and that offers a minimum rating of 90 °C (194 °F). Bosch recommends that all wiring be double insulated, use flexible copper (Cu) conductors at least 3mm in diameter (AWG 12) and rated as USE-2 or equivalent.
  • Page 14: Grounding

    CAUTION DO NOT connect or disconnect a Bosch Solar Energy module unless the array string is open- circuited or all of the modules in the a r r a y string are covered. Take appropriate steps to black out the top (cell side) of the solar modules as much as possible.
  • Page 15 Torque t h e hex bolt (if used) to 50-70 in-lbs. This ground hardware can accommodate a 14AWG through 4AWG bare (stranded or solid) wire. Copyright Bosch Solar Energy Corp., version 1.0 Page 15 of 19...
  • Page 16: Storing, Transporting And Unpacking Solar Modules

    8. STORING, TRANSPORTING AND UNPACKING SOLAR MODULES A. Packaging Bosch Solar Energy modules are shipped in pallet box assemblies that are specially designed to provide the proper protection during shipment. The pallet box consists of the following components: 1) Wooden pallet...
  • Page 17: Unpacking Instructions

    B. Unpacking Instructions Bosch Solar Energy modules are shipped in a pallet box assembly as shown in Figure 8B. To unpack the assembly, please use the following procedure: 1) Cut the polyethylene straps with cutting tools. 2) Remove the upper cap.
  • Page 18: Product Support

    Be sure to take precautions against electric shock in the event of any defects. Any faults must be rectified promptly. Should any repairs become necessary to a Bosch Solar Energy module, it is essential that you contact Bosch Solar Energy. Never under any circumstances attempt to repair the solar module yourself! Bosch Solar Energy modules must only be serviced by specialist firms authorized by Bosch;...
  • Page 19: End Of Life

    It is the responsibility of the user to ensure that this product is disposed of properly. Please contact your local waste disposal center or Bosch Solar Energy if you have any questions concerning the proper disposal of this product.