REMOVING THE FILTERS
CAUTION: Turn off the air purifier and wait 60 seconds before removing
the grille to clean filters.
The ifD
filters come installed within the air cleaner.
®
• Turn-off the air cleaner. Wait 60 seconds and unplug the unit before
removing the grille.
• Press down on the tab on the rear grille and pull the grille down and
toward you. Remove the grille (Fig. 6).
• With one hand, hold the air purifier steady and use other hand to grasp
the ifD
filter. Repeat for the second ifD
filter.
®
®
• To place the ifD
filters back into the air purifier housing, insert at bottom and ensure it is pushed in as
®
far as it can go, then push in from the top. Repeat for the second ifD
• The air cleaner will not turn on if the ifD
filters or the rear grille are not seated properly.
®
CLEANING THE IFD
FILTERS
®
The ifD
filters should be cleaned approximately every 3 months.
®
Turn the power off and unplug the air purifier. After removing the ifD
from the air purifier, follow the steps below to clean the ifD
• Rinse the filters with clean tap water (Fig. 7).
• If the filters still appear dirty, proceed to "Washing,"otherwise proceed
to "Drying."
Washing:
• Remove the ifD
filters from the unit.
®
• Fill a sink with lukewarm water and add a few drops of mild dish soap.
• Gently swish the filters in the soap solution to clean.
• Soak the filters for 2-3 minutes. Do not leave for an extended period of time.
• Rinse the filters with clean tap water (Fig. 7) and proceed to "Drying".
Drying:
• Shake the filters to remove any excess water.
• Place the filters with the honeycomb side down on a plush towel.
• Note that the filters may still be discolored even after washing.
This is acceptable and will not affect performance.
• Allow the ifD
filters to dry for a few hours or overnight.
®
filters are completely dry, place back into the air purifier.
• When the ifD
®
CAUTION:
• Never place wet ifD
filters in your air purifier.
®
• The ifD
filters are NOT dishwasher safe. Do not place the ifD
®
to other extreme hot water conditions.
• Do not use any solvents, strong cleaning agents or flammable liquids to clean the ifD
4
HFD120_HFD120TGT_HFD140_OM_A000359R0_r15_25FEB16.indd 4-5
Fig. 6
filter.
®
Fig. 7
filters
®
filters.
®
filters in a dishwasher or subject them
®
filters.
®
MAINTAINING YOUR WASHABLE PRE-FILTER
The pre-filter helps capture large airborne particles that
enter the rear grille. This pre-filter can be periodically
removed and shaken to clean it. Alternatively, it can be
rinsed by hand under warm water (Fig. 8).
Let the pre-filter air dry completely before
inserting back into the grille (Fig. 9).
If you need to replace this item, please call
1-800-477-0457.
OPTIONAL: Changing the Odor Adsorbing Pre-Filter
If you have chosen the use the odor adsorbing
your air purifier, it will lose its effectiveness for odor adsorption over time
and will need to be replaced.
To purchase additional
Pre-filters, see Accessories section below.
K
If using the odor adsorbing pre-filter, it is recommended that you store the
original washable pre-filter in the event that you decide to use it in the future.
To insert it into the unit, simply place securely into the rear grille in lieu of
standard pre-filter as shown in Fig. 9.
NOTE: The odor adsorbing pre-filter is not washable.
CLEANING AND STORAGE
We recommend that you clean the air purifier at least every 3 months and before extended storage. Use
only a dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, WAX POLISH, OR
ANY CHEMICAL SOLUTION.
ACCESSORIES AND REPLACEMENT FILTERS
There is an optional pre-filter that can be purchased and used with this air purifier that will help reduce
common household odors and VOCs. This
Pre-filter (HRF-K2) can be used in lieu of the permanent
K
washable pre-filter that is supplied with the air purifier. The optional
3 months for optimum odor and VOC reduction performance.
You may purchase Honeywell replacement Odor & VOC Reducing Pre-filter
purchased your air purifier or they can be ordered directly from www.replacementfilters.com.
If you have any questions about the ifD
filters or the washable Pre-filter (T. 3024), call Consumer
®
Relations at 1-800-477-0457 or email consumerrelations@kaz.com.
FREQUENTLY ASKED QUESTIONS
How do I use the additional pre-filter that is packed in the plastic bag?
Your air purifier came with an installed washable pre-filter that helps capture the larger airborne
®
particles before they reach the ifD
filters. If you would like the additional benefit of odor & VOC
reduction, you may replace the washable pre-filter with the Odor & VOC Reducing
packed in a plastic bag with the purifier. You must first remove the washable pre-filter that came in your
air purifier and replace it with the
K
pre-filter. This pre-filter is not washable and should be replaced
every 3 months for optimum performance.
Fig. 8
Fig.9
Washable
Pre-filter
(or optional
Odor & VOC
Reducing
K
Pre-filter that came with
Pre-filter)
K
Rear Grille
Pre-filter should be replaced every
K
at the store where you
K
Pre-filter that was
K
5
2/25/16 12:29 PM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quietclean hfd140 seriesQuietclean hfd-120Quietclean hfd-120tgtQuietclean hfd140

Table of Contents